Barco 08-0311105-00 Air Conditioner User Manual


 
Encore VPx Installation Guide • 08-0311105-00 Rev 00 11
båÅçêÉ=smñ=fåëí~ää~íáçå=dìáÇÉ
VPx Hardware
14) Unit ID Selector
One 16-position selector (with physical digits 0 - 15) is provided for setting an
unique ID on a VPx The selector enables you to assign logical IDs 1 to 16.
By default, a VPx is configured as an DHCP Client, and it automatically obtains
an IP address when it sees a DHCP Server. Controller Models SC and LC are
configured (by default) as DHCP Servers.
15) Serial Port
One 9-pin D connector is provided for RS-232 serial communications with VPx.
16) AC Connector
One AC Connector is provided to connect the VPx to your AC source.
See the “Program Output Notes
” section on page 14 for more information on VPx outputs.
Note
Physical digit 0 equates to logical ID 16.
Note
Always ensure that each VPx has a unique ID. During setup,
the ID is used during various configuration procedures.
Note
Using the Miscellaneous Menu, you can re-define IDs using
numbers 17 - 32. In Chapter 5 of the Encore Presentation
System User’s Guide, refer to the “Miscellaneous Menu
section for details.