12 Installation (for qualified installers only)
© Travis Industries 4060111 100-01175
Face Mounting Brackets -- Arched, Metropolitan, Artisan Vict. Lace Faces
Some Arched, Artisan, Metropolitan, and Victorian Lace Faces include old brackets that will not
mount to the heater (see illustration below). For these faces, make sure to use the new mounting
brackets (either included with the heater or available through your dealer - SKU 225-20055).
WARNING: When attaching the Victorian Lace Face, do not over-tighten the screws. Over-
tightening the screws may damage the face – simply tighten the screws until they contact the face.
Old Arched,
Metropolitan, or
Artisan Bracket
New
Bracket
Old Victorian
Lace
Bracket
Install the face mounting
brackets to the heater with the
included nuts.
NOTE: The brackets
install with this pair of
closely spaced flanges
at the top.
NOTE: The face attaches to the brackets with the screws included with the face – see the
instructions included with the face.
Mounting the Bedford Face
Some Bedford Faces include old brackets that
will not mount to the heater. For these faces,
make sure to use the new DVS Insert EF II Face
Upgrade Kit (either included with the face or
available through your dealer - SKU 250-
00029). The kit lowers the face and surround
panels 1-1/4”. This means you must install this
with a raised fireplace or raise the insert 1-1/4”
above the hearth. To do this you may extend
the leveling bolts or place bricks or other non-
combustible under the insert.
1-1/4