24 Operation
Travis Industries 4050225 100-01154
Start-Up Sequence
This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started
when cold. This is to ensure proper operation through all possible settings and operational states (hot
or cold, pellets burning or not burning, etc.). This sequence over-rides all user settings (except the
"OFF" position) to set the auger feed rate to medium, the exhaust blower to high, and the igniter on.
During this period the lowest HEAT OUTPUT light will flash.
"MANUAL AUGER" Button
This button turns the auger on. It is used to prime the auger after the hopper has run out of pellets.
"AUGER ON" Light
This light comes on when the auger is turning. This allows the operator to determine when the auger
is turning.
"FAULT" Light
This light comes on when an error occurs:
The stove runs out of pellets
During initial start-up (for a split
second) or for improper electrical
frequency
A start-up sequence that does not
result in the heater coming up to
temperature
To reset the fault light, turn the mode switch to
off and re-start the stove.
HIGH
DISCONNECT POWER BEFORE SERVICE
REMOTE
AUTO
MANUAL
H
E
A
T
O
U
T
P
U
T
MED
LOW
AUGER
FAULT
Fault Codes (for qualified service personnel only)
Fault and #2 (LOW) Light Flash = Flow Switch Fault
Fault and # 4 (MID) Light Flash = System Snap Disk Fault (pellets run out & stove goes cold)
Fault and # 6 (HIGH) Light Flash = Safety Snap Disk Fault
Power Outages
If a sustained power outage occurs while in "Manual", the stove will go to a "cool down" mode to
vacate smoke once power returns. If the power outage was short, the heater will go to the start-up
sequence. If in "Auto", the stove will re-start (if the room is cool).
! Because this stove relies upon a blower to evacuate the smoke, some smoke may enter
the home during a power outage. To keep to a minimum, leave the door closed.