Avalon Stoves Avalon Pellet Stove Astoria PS Stove User Manual


 
20 Operation
Travis Industries 4050225 100-01154
Loading Pellets
Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper
holds approximately 115 pounds of pellets.
Make sure pellets
are not left on this
heat shield.
P
e
t
e
l
s
l
To Close the Hopper Lid:
lift the lid, pull this tab forward,
then lower the lid down.
To Open the Hopper Lid:
lift the hopper lid from this handle.
These notches allow
you to open the hopper
lid to the level you wish.
Warning:
The front edge of the
hopper lid becomes very
hot, do not touch the area
below the handle.
The Two Modes of Operation:
Manual
Manual mode requires the user to turn
the heater on and off manually.
Auto (requires a thermostat)
Auto mode allows you to use a
thermostat to control room
temperature. The stove automatically
turns on when the temperature drops
below the thermostat setting. Once the
stove reaches operating temperature,
the stove then runs at the heat output
setting selected.
Switching Modes While in
Operation
Whenever the stove is switched from
one mode to another while in
operation, the stove will enter the "start-
up" sequence for a minimum of 20
minutes.
HIGH
DISCONNECT POWER BEFORE SERVICE
REMOTE
AUTO
MANUAL
H
E
A
T
O
U
T
P
U
T
MED
LOW
AUGER
FAULT
AUTO
OFF
MANUAL
H
E
A
T
F
A
N
UP
DOWN
UP
DOWN
MANUAL
MANUAL
START
AUGER
TRAVIS INDUSTRIES
HOUSE OF FIRE
TM
Use the mode
switch to
determine the
mode.
These indicator lights
are used to determine
which mode you are in.
NOTE: if using a
modulating remote, this
light will come on to
indicate the remote is
controlling the heater.