22 Operation
Travis Industries 4050225 100-01154
Auto Mode
Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns
on when the temperature drops below the thermostat setting. Once the stove reaches operating
temperature, the stove then runs at the heat output setting selected.
To Adjust Room Temperature (or Start the Stove)
Move the thermostat to the heat setting desired. If the room is
cooler than the setting, the stove will go through the start-up
sequence for approximately 10 minutes. During this period the
lowest “HEAT OUTPUT” light will flash. Once up to temperature,
the stove will then run at the heat output setting selected on the
control panel. If the room is too hot, move the thermostat to a
lesser setting.
To Adjust the Heat
Press the "Heat” buttons to adjust the heat
output.
HINT:
If you find that the stove turns on and off
repeatedly, you may wish to turn the heat
output to a lesser setting. The lower setting
will provide a more consistent heat output over
time, eliminating the need for the thermostat to
repeatedly turn the stove off.
NOTE:
If the thermostat calls for heat while the stove is
still cooling down, the stove will go through the
start-up sequence (for a minimum of 20
minutes).
HIGH
DISCONNECT POWER BEFORE SERVICE
REMOTE
AUTO
MANUAL
H
E
A
T
O
U
T
P
U
T
MED
LOW
AUGER
FAULT
AUTO
OFF
MANUAL
H
E
A
T
F
A
N
UP
DOWN
UP
DOWN
MANUAL
MANUAL
START
AUGER
TRAVIS INDUSTRIES
HOUSE OF FIRE
TM
These lights
indicate the
heat output
setting.
NOTE: the
lights may
be difficult to
see from an
angle.
Press the
“up” or
“down”
button to
adjust the
heat output.
To Shut Down
Move the mode switch to "OFF". The exhaust
blower will still run until the heater cools down.
AUTO
OFF
MANUAL
H
E
A
T
F
A
N
UP
DOWN
UP
DOWN
MANUAL
MANUAL
START
AUGER
TRAVIS INDUSTRIES
HOUSE OF FIRE