18 Installation
Travis Industries 4050225 100-01154
Installation Example: Freestanding Masonry Chimney
L Vent
Sections
6 Min.
L Vent
Storm Collar
Vertical Cap
Cover Plate (non-combustible)
Silicone
Seal the cover
plate with silicone.
Allow room for the
hopper lid to open
3
Minimum
Clean-Out Access
Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections.
500° F. RTV
Silicone
57-1/2
L Vent Flex