Determine the location
The equipment interface module (EIM) consists of a relay and an antenna. They can be
installed either in the wiring compartment of the baseboard heater or in a 4-11/16” square
junction box.
Installing the EIM in a baseboard heater
You can install the EIM in the wiring
compartment of the baseboard heater if you
have any of the heaters listed in the following
table:
Installing the EIM in a 4-11/16” square junction box
You can use a 4-11/16” square junction box in either of
the following conditions:
You have a convector or fan-forced heater.
You cannot install or do not wish to install the EIM in
the wiring compartment of the baseboard heater.
Install the Equipment Interface Module (EIM)
2.
Install EIMs at a minimum distance of 2 feet (0.6 m) of each other. This minimum
distance still applies even if the EIMs are on opposite sides of a wall.
Manufacturer / brand Series
Cadet F
Global Commander CCB
King Electrical K, CB, KP, M
Marley 2500, BKOC, QMKC
Ouellet ODBA, ODI, ODIA, OFM, OPR
Stelpro CBB, N, SCA, SCAS
TPI 2900C, 2900S, 3700, 3900
The product has been tested for compatibility with the heaters listed above. If your
heater is not on the list, install the EIM on a 4-11/16” square junction box or replace
it with one listed.
The junction box can be installed anywhere in the
house; for example, near the main electrical panel.
Relay