Arkon Channelmag Water System User Manual


 
19
ChannelMag
Section 2 Installation
2.6 Cable Types
Exciter Coils Electrodes Reference Coils
Black to 4 Black to 24 Black to 31
White to 5 White to 25 White to 32
Shield to 6 Shield to 26 Shield to 19
The junction box is submersible and is potted with a re-enterable gel, but is not intended to be
installed in the media flowing in the channel. Cables from dual sensors are wired in the junction
box as shown below in Section 2.6.2.
ChannelMags are connected to a junction box normally using cables in
flexible 1” (25mm)
conduit. See the ChannelMag Sensor Specification for the standard cable and conduit lengths.
The cables and conduit are stowed for packing against the side of the Magne
tic Enhancement Plates
and are marked “coils,” “electrodes,” and “reference.” The cables from the junction box to the
transmitter are without conduits and connected to the remote transmitter terminals as follows (see
separate instructions for the transmitter):