Section 2 Installation
The height “E” of the magnetic enhancement plates is custom made and normally extends 2”
(50mm) below the top of the channel. The width W is adjustable to fi
t the channel width. W
includes the mounting brackets.
1/4” (6.3mm)
thick base plates
with countersunk
1/4” screws from
the bottom
Note: A CM2/8” sensor is always supplied with ramps.
Cables from each sensor are to run in separate conduits to the
ChannelMag junction box situated above the level of the
flowing media. The cable
runs are omitted in the drawing for clarity.
For Entela approval for Zone 2 or Class 1, Div. 2 areas see notes
in Section 2.6.2.
