Ariens 915057 Air Cleaner User Manual


 
11 - 50
.
Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts manually activated. contact resistance is 0.1-0.3 ohms when correct.
2 sets of contacts, one normally open, one normally closed. Contact resistance is 0.1-0.3 ohms when correct.
Normally open contacts manually activated. Contact Resistance is 0.1-0.3 ohms when correct.
(A) Measure with steering arms in neutral.
Normally open contacts manually activated. Contact resistance is 0.1-0.3 ohms when correct.
(A) Measure with steering arms in neutral.
Key Switch Off Run Start
B 11.50-13.00 Volts 11.50-13.00 Volts 11.50-13.00 Volts
A 11.50-13.00 Volts 11.50-13.00 Volts
S 11.50-13.00 Volts
L 11.50-13.00 Volts 11.50-13.00 Volts
Seat Switch Off Run Start
Red/Yellow 11.50-13.00 Volts 11.50-13.00 Volts
Purple 11.50-13.00 Volts 11.50-13.00 Volts
PTO Switch Off Run Start
Brown 11.50-13.00 Volts
Purple/White Connected to PTO Clutch
Purple 11.50-13.00 Volts 11.50-13.00 Volts
Red/Green 11.50-13.00 Volts 11.50-13.00 Volts
Brown/Yellow 11.50-13.00 Volts
Left Hand Neutral Switch (A) Off Run Start
Brown/Yellow 11.50-13.00 Volts
White 11.50-13.00 Volts 11.50-13.00 Volts
Right Hand Neutral Switch (A) Off Run Start
Red/Green 11.50-13.00 Volts 11.50-13.00 Volts
White 11.50-13.00 Volts 11.50-13.00 Volts
Yellow/Red 11.50-13.00 Volts 11.50-13.00 Volts