A.O. Smith 28 30 50 60 Water Heater User Manual


 
Installation
28 Instruction Manual BFC
3
is
3.9.1 Concentric wall flue terminal
Table 3.8 shows the wall flue terminal prescribed by A.O. Smith (installation
type C13).
Figure 3.4 Wall flue terminal
A
B
IMD-0075
Table 3.8 Concentric wall flue terminal specifications
Specification Description
Manufacturer Muelink & Grol
Model M2000 MDV SE
(1)
Pipe material, flue gas discharge Thick-walled aluminium with lip ring seal
Pipe material, air intake Thin-walled galvanised sheet steel
Pipe diameter Concentric
BFC 28: Ø 80/125 mm.
BFC 30, 50 and 60: Ø 100/150 mm.
1. The M2000 MDV SE model is a special version of the Mugro 3000 series. No other wall flue terminal may be used, as the
BFC-appliance is approved exclusively for this model of wall flue terminal. You can order the wall flue terminal from A.O. Smith or your
trade supplier, by specifying model: M2000 MDV SE.