A.O. Smith 28 30 50 60 Water Heater User Manual


 
Introduction
Release R.1.3 UK 17
is
3 Installation
Warning
The installation should be carried out by an approved installer in compliance
with the general and local regulations imposed by the gas, water and power
supply companies and the fire service.
The appliance may only be installed in a room which complies with the
requirements stated in national and local ventilation regulations.
Refer also to paragraph ’1.3 Regulations’.
3.1 Introduction This chapter describes the installation activities to be carried out before the
appliance may be started up, namely:
Packaging;
Environmental conditions;
Technical specifications;
Water connections, Unvented;
Water connections, Vented;
Gas connection;
Air supply and flue gas discharge;
Electrical connection;
Checking the supply pressure and burner pressure;
Conversion to a different gas category.
n Remark
Starting up the appliance is described in chapter ’7 Starting up and shutting
down’.
3.2 Packaging To avoid damaging the appliance, remove the packaging carefully. We
recommend unpacking the appliance at or near its intended location.
cNote
The appliance may only be manoeuvred in an upright position. Take care
that the appliance is not damaged after unpacking.
3.3 Environmental
conditions
The BFC appliance is a room-sealed appliance. Installation types possible with
this appliance are C13, C33, C43, C53 and C63. This makes it possible to install
the appliance in either a closed or an open boiler room.
is