21
lines. Contact the local water heater supplier or service agency
for further information concerning an Anode Replacement Kit
and this chlorination treatment.
If the smelly water persists after the anode replacement and
chlorination treatment, we can only suggest that chlorination or
aeration of the water supply be considered to eliminate the water
problem.
Do not remove the anode leaving the tank unprotected. By doing
so, all warranty on the water heater tank is voided.
“AIR” IN HOT WATER FAUCETS
HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of time
(generally two weeks or more). Hydrogen gas is extremely fl am-
mable and explosive. To prevent the possibility of injury under
these conditions, we recommend the hot water faucet, located
farthest away, be opened for several minutes before any electri-
cal appliances which are connected to the hot water system are
used (such as a dishwasher or washing machine). If hydrogen
gas is present, there will probably be an unusual sound similar to
air escaping through the pipe as the hot water faucet is opened.
There must be no smoking or open fl ame near the faucet at the
time it is open.
HIGH WATER TEMPERATURE SHUT OFF SYSTEM
This water heater is equipped with an automatic gas shut-off
system. This system works when high water temperatures are
present. Turn “OFF” the entire gas supply to the water heater.
The high temperature shut-off is built into the gas control valve.
It is non-resettable. If the high temperature shut-off activates, the
gas control valve must be replaced. Contact your gas supplier
or service agency.