397763-YTG-B-0508
18 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO. THGD24S41S1
INDOOR COIL MODEL NO. AHP30
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 600 800 1000
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 22.9 26.4 25.6 29.2 31.5 25.8 28.0 27.2 30.7 33.2 28.8 29.6 28.8 32.2 35.0
S.C. 21.8 20.2 17.3 17.7 15.1 24.6 23.7 19.4 19.6 16.2 27.4 27.2 21.5 21.6 17.4
KW 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5
75
T.C. 21.9 24.6 24.1 27.3 29.5 24.5 26.0 25.5 28.6 31.1 27.0 27.4 26.9 30.0 32.6
S.C. 20.8 19.4 16.5 16.8 14.3 23.3 22.4 18.6 18.8 15.4 25.7 25.4 20.7 20.8 16.5
KW 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
85
T.C. 20.9 22.9 22.6 25.3 27.6 23.1 24.1 23.7 26.5 28.9 25.3 25.3 24.9 27.8 30.3
S.C. 19.9 18.6 15.8 16.0 13.4 22.0 21.2 17.9 18.0 14.5 24.1 23.7 20.0 20.0 15.6
KW 1.7 1.7 1.7 1.7 1.8 1.7 1.7 1.7 1.8 1.8 1.8 1.7 1.7 1.8 1.8
95
T.C. 19.8 21.1 21.0 23.4 25.6 21.7 22.1 22.0 24.5 26.8 23.5 23.1 23.0 25.6 27.9
S.C. 18.9 17.8 15.0 15.1 12.6 20.6 19.9 17.1 17.2 13.7 22.4 22.0 19.2 19.2 14.8
KW 1.8 1.8 1.8 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9 1.9
105
T.C. 18.4 19.1 19.2 21.5 23.5 20.1 20.3 20.0 22.3 24.5 21.8 21.5 20.8 23.2 25.5
S.C. 17.6 16.7 14.3 14.4 11.7 19.2 18.6 16.2 16.4 12.8 20.8 20.5 18.1 18.4 13.9
KW 1.9 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1
115
T.C. 17.1 17.3 17.4 19.6 21.5 18.6 18.6 18.0 20.2 22.3 20.1 20.0 18.7 20.9 23.1
S.C. 16.3 15.7 13.5 13.6 10.8 17.7 17.4 15.2 15.6 12.0 19.2 19.1 16.9 17.6 13.1
KW 2.1 2.1 2.1 2.1 2.2 2.1 2.1 2.1 2.1 2.2 2.2 2.2 2.1 2.2 2.2
125
T.C. 15.8 15.4 15.6 17.7 19.5 17.1 17.0 16.1 18.2 20.1 18.5 18.5 16.6 18.6 20.7
S.C. 15.0 14.7 12.7 12.9 10.0 16.3 16.1 14.3 14.9 11.1 17.6 17.6 15.8 16.9 12.2
KW 2.2 2.2 2.2 2.2 2.3 2.2 2.2 2.2 2.3 2.3 2.3 2.3 2.2 2.3 2.3
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handler Coil T.C. S.C. KW
– FC/MC/PC24 0.98 0.98 1.00
– FC/MC/PC30 0.98 0.98 1.00
– FC/MC/PC32 1.00 1.00 1.00
– FC/MC/PC35 1.00 1.00 1.00
– HC30 0.98 0.99 1.00
– HC36 1.00 1.00 1.00
– HD36 0.98 0.94 1.00
AHP30 – 0.99 0.98 1.00
AV24 – 0.99 0.98 1.00
AV36 – 1.03 1.03 1.00
F4FP030 – 0.99 0.97 1.00
MA08B FC/MC/PC24B 0.98 0.98 1.00
MV12B FC/MC/PC24B 1.01 1.00 1.00
MA08B FC/MC/PC30B 0.98 0.98 1.00
MV12B FC/MC/PC30B 1.01 1.01 1.00
MA08B FC/MC/PC35B 1.00 1.00 1.00
MV12B FC/MC/PC35B 1.02 1.02 1.00
MV16C FC/MC/PC35C 1.02 1.02 1.00
Variable Speed
Furnace
Coil T.C. S.C. KW
PV8*A12 FC/MC/PC24A 1.00 0.98 1.00
PV9*A12 FC/MC/PC24A 1.00 1.00 1.00
P(C,V)9*B12 FC/MC/PC24B 1.00 1.00 1.00
PV8*A12 FC/MC/PC30A 1.00 0.98 1.00
PV9*A12 FC/MC/PC30A 1.00 1.00 1.00
P(C,V)9*B12 FC/MC/PC30B 1.00 1.00 1.00
PV8*A12 FC/MC/PC32A 1.01 1.00 1.00
PV9*A12 FC/MC/PC32A 1.01 1.01 1.00
P(C,V)9*B12 FC/MC/PC35B 1.02 1.02 1.00
P(C,V)9*C16 FC/MC/PC35C 1.03 1.06 1.00
PV8*A12 HC30A 1.00 0.99 1.00
PV9*A12 HC30A 1.00 1.00 1.00
P(C,V)9*B12 HC36B 1.02 1.02 1.00
PV8*A12 HD36A 0.99 0.95 1.00
PV9*A12 HD36A 1.00 0.96 1.00
P(C,V)9*B12 HD36B 1.00 0.96 1.00