A SERVICE OF

logo

¾ R detect: When the port doesn't connect with any PD, the POE switch will poll each
port and detects the resistor.
Dsvry R (ohms): display resistance value.
Port Curr (mA): display current value.
Port Volt (V): display voltage value.
Port Pwr (W): display watt value.
Class Curr(mA): display power class. When you enable the "Bypass classification" function,
the class value will not show in here.
Firmware Version: display the system firmware version.
Total Port Power (W): total of all the port power that provided to PD.
Power Management: status of the power management function.
Total Power Limit: total power of the total ports' output power.
Commands
Select command: enter the POE command number or Power supply management command
integer in the prompt and press enter. The Power supply management command will show
up when the Port PwrLimit Mangag. is enabling.
Command Description
[1] Power Management (Enable)
Enabling or disabling the POE power
management function.
[2] Set Port Enable (ON/OFF)
Enabling or disabling the port POE inject function
[3]. Set Port PwrLimitClass. (ON/OFF)
Enabling or disabling per port power output limit.
When is enabling, per port power output limit will
follow the value that set in power limit max.
[4] Set Port PwrLimitManag. (ON/OFF)
Enabling or disabling the port power limit
management for power supply management.
[5] Set Port DetectLegacy
Enabling the port power legacy detect.
[6] Set Port Priority (1:C 2:H 3:L)
Set port priority for the power supply
management.
[7] Set Power Limit Max (<15400)
Set the port power output limit value. The
maximum value must less than 15400.
[a] Auto Refresh [OFF]
Enabling or disabling auto refresh system
parameters.