![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/ba/8ba42d4f-8a8c-436f-b331-c82ae47d4641/8ba42d4f-8a8c-436f-b331-c82ae47d4641-bg124.png)
MEDIA CHANGER COMMANDS M2488 PRODUCT GUIDE
6-32 CG00000-011503 REV. A March 1997
6-3 ADDITIONAL COMMAND INFORMATION ON MEDIUM CHANGER
MODE SELECT AND MODE SENSE COMMANDS
Table 6-35 lists the page codes supported by the Medium Changer MODE SELECT and MODE
SENSE commands.
** NOTE **
The current value of non-changeable Mode Parameters must be
returned in MODE SELECT command data.
6-3.1 Page Code 00h, Device Unique Parameters
Table 6-35. Page Codes
PAGE CODE DESCRIPTION
00h Device Unique Parameters
1Dh Element Address Assignments
1Eh Transport Geometry Parameters
1Fh Device Capabilities
Table 6-36. Page Code 00 - Device Unique Parameters
BITS MODE SENSE
DEFAULT
VALUES
ACL FACL
BYTES 7 6 5 4 3 2 1 0
0
PS * Reserved Page Code 80h
1
Additional Page Length 0Eh
2
Reserved
HltLd Eject Code Mode Code 09h 01h
3
Position 00h
4 - 7
Cartridge Map 00000000h
8 - 15
Reserved 00h
* The PS bit must be set to 0 on a MODE SELECT command.
Bits are changeable
Changeable only if ACL attached.