M2488 PRODUCT GUIDE TAPE UNIT PARAMETERS
April 1997 CG00000-011503 REV. A 5-11
5-2.6 Device Configuration Parameters
** NOTE **
The only fields that may be modified in this page are Read Buffer
Empty Ratio, the SOCF field, Read Buffer Empty Ratio, the RBO bit
and the Select Data Compression Algorithm field. On a MODE
SENSE command, only these fields are reported as changeable.
Table 5-12. Page 10h - Device Configuration Parameters
BITS MODE
SENSE
DEFAULT
VALUES
BYTES
76543210
0
PS * Reserved Page Code 90h
1
Additional Page Length 0Eh
2
Reserved CAP CAF Active Format 00h
3
Active Partition 00h
4
Write Buffer Full Ratio 80h
5
Read Buffer Empty Ratio 40h
6-7
Write Delay Time 0032h
8
DBR BIS Reserved AVC
SOCF RBO REW C4h
9
Gap Size 00h
10
EOD Defined EEG SEW Reserved 00h
11-13
Buffer Size at Early Warning 060000h
14
Select Data Compression Algorithm 01h
15
Reserved 00h
* The PS bit must be set to 0 on a MODE SELECT command.
Note: Changeable fields in the page are shaded.