Yukon Advanced Optics Oil Furnace Furnace User Manual


 
14
Installation
FIG. 6
FIG. 7
PLACE FURNACE
Review all instructions in the Planning Your
Installation section. Place the furnace in the pre-
selected location.
Refer to Figs. 4 & 5 (on page 12) in the Planning
Your Installation section. Make sure the furnace is
level.
SECONDARY AIR INTAKE COVER
1. Remove secondary air intake cover from
accessory package and align over mounting
holes located above fire door assembly on face
of furnace. See Fig. 7.
2. Insert 12 ea. # 10 x 3/4 hex HD drill screws
(furnished with cover) through mounting holes
and tighten.
SECONDARY AIR SHUT OFF
MODELS LWO-112 & LWG-112 ONLY
1. Remove round secondary air shut off disc from
plastic bag.
2. Screw disc to the intake cover just installed.
Opening the disc when burning wood provides
room air to the round perforated tubes between
the top and bottom row of firebrick, thereby
causing secondary combustion of the unburned
wood gases as they leave the initial flame. This
patented feature increases wood burning
efficiency up to 40% while reducing smoke and
creosote. When burning gas or oil for extended
periods of time, this disc should be closed.
It is not necessary to provide this disc on models
LWG- 168 and LWO-168. Maximum efficiency is
achieved without this disc.
DRAFT TUBE INSTALLATION
Remove the 8 bolts already screwed in where
draft tube gasket is in place. Mount tube over
gasket. Make sure the gasket aligns with the long
slotted hole. Bolt tube to the furnace below the fire
door. See Fig. 7 & 8.
Questions? Visit www.yukon-eagle.com or call 1-800-358-0060
FIG. 8
Secondary Air
Shut Off Disc
DRAFT TUBE
SMOKE
PIPE
RETURN AIR
PLENUM
WARM AIR
PLENUM
FUME SWITCH
(GAS MODEL ONLY)
DS-103 DAMPER
CONTROL
24-VOLT
TRANSFORMER