York YHJF18 THRU 60 Heat Pump User Manual


 
510667-YTG-B-0509
Johnson Controls Unitary Products 9
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
YHJF36S41S1
T*(8,L)X*A12 FC/MC/PC37A 36.0 3.80 2.78 24.6 2.54 2.84 8.50
T*(8,L)X*B12 FC/MC/PC43B 36.0 3.80 2.78 24.6 2.54 2.84 8.50
T*(8,L)X*C16 FC/MC/PC43C 36.0 3.78 2.79 24.0 2.56 2.75 9.00
T*(8,L)X*C20 FC/MC/PC43C 36.0 3.88 2.72 24.4 2.60 2.75 9.00
T*9X*B12 FC/MC/PC43B 36.0 3.80 2.78 24.6 2.54 2.84 8.50
T*9X*C16 FC/MC/PC43C 36.0 3.82 2.76 24.4 2.56 2.79 8.50
T*9X*C20 FC/MC/PC43C 36.0 3.74 2.82 24.2 2.52 2.81 8.50
Y*(8,L)C*C16 FC/MC/PC43C 36.0 3.72 2.84 24.4 2.50 2.86 8.50
Y*(8,L)C*C20 FC/MC/PC43C 36.0 3.74 2.82 24.2 2.52 2.81 8.50
(Y*9C/T*9V)*C16 FC/MC/PC43C 36.0 3.76 2.81 24.6 2.52 2.86 8.50
(Y*9C/T*9V)*C20 FC/MC/PC43C 36.0 3.70 2.85 24.4 2.50 2.86 8.50
YHJF42S41S1
T*(8,L)X*C16 FC/MC62D 40.5 4.06 2.92 26.0 2.78 2.74 9.00
T*(8,L)X*C20 FC/MC62D 41.0 4.08 2.94 26.2 2.78 2.76 9.00
T*9X*C16 FC/MC62D 41.0 3.98 3.02 26.2 2.72 2.82 9.00
T*9X*C20 FC/MC62D 40.5 4.02 2.95 26.2 2.74 2.80 9.00
T*9X*D20 FC/MC62D 40.5 4.02 2.95 26.0 2.76 2.76 9.00
Y*(8,L)C*C16 FC/MC62D 41.0 3.96 3.03 26.4 2.70 2.86 9.00
Y*(8,L)C*C20 FC/MC62D 41.0 4.00 3.00 26.2 2.74 2.80 9.00
(Y*9C/T*9V)*C16 FC/MC62D 41.5 3.86 3.15 26.6 2.64 2.95 9.00
(Y*9C/T*9V)*C20 FC/MC62D 41.0 3.90 3.08 26.4 2.68 2.89 9.00
(Y*9C/T*9V)*D20 FC/MC62D 41.0 3.94 3.05 26.4 2.70 2.86 9.00
YHJF48S41S1
T*(8,L)X*C16 FC/MC62D 48.0 3.78 3.72 32.0 2.56 3.66 9.00
T*(8,L)X*C20 FC/MC62D 48.0 3.80 3.70 31.8 2.58 3.61 9.00
T*9X*C16 FC/MC62D 48.0 3.76 3.74 32.0 2.56 3.66 9.00
T*9X*C20 FC/MC62D 48.0 3.80 3.70 32.0 2.58 3.63 9.00
T*9X*D20 FC/MC62D 48.0 3.76 3.74 32.0 2.56 3.66 9.00
Y*(8,L)C*C20 FC/MC62D 48.0 3.76 3.74 32.0 2.56 3.66 9.00
(Y*9C/T*9V)*C16 FC/MC62D 48.0 3.72 3.78 32.2 2.54 3.71 9.00
(Y*9C/T*9V)*C20 FC/MC62D 48.0 3.68 3.82 32.4 2.50 3.80 9.00
(Y*9C/T*9V)*D20 FC/MC62D 48.0 3.72 3.78 32.2 2.52 3.74 9.00
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)
MODEL
FURNACE
MODEL
COIL
1
MODEL
ARI HEATING
2
47F17F HSPF
MBH COP KW MBH COP KW STD