York YHJF18 THRU 60 Heat Pump User Manual


 
510667-YTG-B-0509
Johnson Controls Unitary Products 11
SOUND LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
* Rated in accordance with ARI 270-2008 Standards.
TYPICAL INSTALLATION
TYPICAL FIELD WIRING
Size
Test Condition 63 125 250 500 1000 2000 4000 8000 dBA SQI
RSS Sound Power Calibration 1091 402 82.8 85.4 85.9 85.3 88.1 88.6 86.6 83.9
18
Cooling Mode 67.3 69.2 64.6 67.3 65.5 61.5 58.2 51.8 70.0 19.21
Heating Mode 68.9 69.0 64.0 66.4 66.6 59.6 56.4 52.6 69.7 19.17
24
Cooling Mode
69.9 73.1 64.2 65.2 66.3 61.2 58.8 52.4 69.9 19.03
Heating Mode
72.4 71.6 64.8 68.3 68.0 62.2 60.1 53.0 71.6 18.99
30
Cooling Mode 70.5 68.8 64.3 65.3 65.5 60.3 55.8 50.6 69.0 19.01
Heating Mode 72.2 70.1 67.5 66.7 69.4 62.5 58.3 52.7 72.0 19.03
36
Cooling Mode 70.9 69.3 65.3 66.4 66.3 59.7 56.7 50.8 69.6 19.14
Heating Mode 73.2 70.1 66.9 68.5 68.4 61.6 59.4 55.5 71.7 19.12
42
Cooling Mode 71.7 69.5 72.1 69.0 71.3 60.6 56.9 54.0 73.3 19.01
Heating Mode 72.6 72.6 68.1 70.5 70.9 62.7 59.2 56.9 73.6 19.02
48
Cooling Mode 71.0 71.0 68.4 68.1 67.9 60.1 55.8 51.3 70.8 19.11
Heating Mode 73.6 72.5 74.0 73.6 75.8 64.0 63.2 56.8 77.6 19.08
60
Cooling Mode - High Stage 71.2 69.4 71.4 73.2 71.2 61.1 57.6 52.8 74.7 19.09
Heating Mode - High Stage 71.6 72.7 69.6 71.3 72.4 63.4 61.5 57.4 75.0 19.05
THERMOSTAT
SEALOPENING(S)WITH
PERMAGUMOR EQUIVALENT
TOINDOOR COIL
TOFURNACE OR
AIRHANDLER
TERMINALBLOCK
NECCLASS 2WIRING
NECCLASS 1WIRING
ALLOUTDOORWIRING
MUSTBE WEATHERPROOF.
CONTROL
ACCESS
PANEL
WEATHERPROOF
DISCONNECT
SWITCH
MINIMUM24” SERVICE
ACCESSCLEARANCE
ONONE SIDE
48”OVERHEAD
CLEARANCE
10”CLEARANCE
AROUNDPERIMETER
NOTE:
THERMOSTAT
INDOOR UNIT
OUTDOOR UNIT
LOWVOLTAGETERMINALBLOCK
INAIRHANDLERWITH ELECTRICHEAT
DEFROST
CONTROL
FIELD
INSTALLED
JUMPER
DEHUMIDIFICATIONCONTROLCONNECTION
(Humidistat*Jumpermust beremoved)
GND.
SCREW
CONTACTOR
T2
T1
L2
L1
M
R
LorX
Y
O
W
G
T
2
E
2
R
R
Y
Y
O
O
W2
W
W1
C
C
X/L
G
W1
BK
GND.
LUG
CIRCUIT
BREAKER***
POWERWIRING
24VCONTROLWIRING
(NECCLASS 2)
JUMPERTERMINALSEANDW TOHEAT
ONFIRSTSTAGEDURINGEMERGENCYHEAT.
TERMINALNOTUSEDONALLTHERMOSTATS.
POWERWIRING
208/230-1-60
230-1-50
CHECKTHELOW VOLTAGETERMINALBLOCKONTHE INDOORUNITFORTHEACTUALARRANGEMENT OFTHE TERMINALS.
CONNECTPOWERWIRING TOTERMINALBLOCK3TBON UNITSWITHOUTELECTRICHEATORCIRCUITBREAKER.
BorC
ALL FIELD WIRING TO BE IN ACCORDANCE WITH ELECTRIC CODE (NEC) AND/OR LOCAL CODES
RED
BLK
YEL
ORG
BRN
PUR
WHT
CC
GRY
/66
GRAYFORUSEWITH OPTIONALOUTDOORTHERMOSTATKITS.
5
1
2
3
4
5
1
3,4