York YHJF18 THRU 60 Heat Pump User Manual


 
510667-YTG-B-0509
6 Johnson Controls Unitary Products
YHJF36S41S1
T*(8,L)X*A12 FC/MC/PC37A 14 1290 35.8 27.4 14.50 12.00
T*(8,L)X*B12 FC/MC/PC43B 17 1300 35.8 27.4 14.50 12.00
T*(8,L)X*C16 FC/MC/PC43C 21 1175 35.4 26.4 15.00 12.50
T*(8,L)X*C20 FC/MC/PC43C 21 1250 36.0 27.4 15.00 12.50
T*9X*B12 FC/MC/PC43B 17 1270 35.8 27.4 14.50 12.00
T*9X*C16 FC/MC/PC43C 21 1260 36.0 27.4 14.50 12.00
T*9X*C20 FC/MC/PC43C 21 1185 35.2 26.4 14.50 12.00
Y*(8,L)C*C16 FC/MC/PC43C 21 1205 35.2 26.4 14.50 12.00
Y*(8,L)C*C20 FC/MC/PC43C 21 1190 35.2 26.4 14.50 12.00
(Y*9C/T*9V)*C16 FC/MC/PC43C 21 1240 35.6 27.2 14.20 12.00
(Y*9C/T*9V)*C20 FC/MC/PC43C 21 1200 35.2 26.4 14.35 12.00
YHJF42S41S1
T*(8,L)X*C16 FC/MC62D 21 1360 40.5 31.0 15.00 12.50
T*(8,L)X*C20 FC/MC62D 21 1485 40.5 31.8 15.00 12.50
T*9X*C16 FC/MC62D 21 1460 40.0 30.8 14.50 12.00
T*9X*C20 FC/MC62D 21 1460 40.5 31.0 14.50 12.00
T*9X*D20 FC/MC62D 24 1425 40.5 31.0 14.50 12.00
Y*(8,L)C*C16 FC/MC62D 21 1420 40.0 30.8 14.40 12.00
Y*(8,L)C*C20 FC/MC62D 21 1410 40.5 30.8 14.50 12.00
(Y*9C/T*9V)*C20 FC/MC62D 21 1445 40.0 30.6 14.05 11.90
(Y*9C/T*9V)*D20 FC/MC62D 24 1455 40.0 30.6 14.25 12.00
YHJF48S41S1
T*(8,L)X*C16 FC/MC62D 21 1610 48.0 36.2 14.50 12.00
T*(8,L)X*C20 FC/MC62D 21 1665 48.0 36.2 14.50 12.00
T*9X*C16 FC/MC62D 21 1550 48.0 36.0 14.50 12.00
T*9X*C20 FC/MC62D 21 1595 48.0 36.2 14.50 12.00
T*9X*D20 FC/MC62D 24 1610 48.0 36.0 14.50 12.00
Y*(8,L)C*C16 FC/MC62D 21 1635 48.0 36.0 14.50 12.00
Y*(8,L)C*C20 FC/MC62D 21 1615 48.0 36.0 14.50 12.00
(Y*9C/T*9V)*C16 FC/MC62D 21 1590 47.5 36.0 14.35 12.00
(Y*9C/T*9V)*C20 FC/MC62D 21 1655 47.5 35.8 14.05 12.00
(Y*9C/T*9V)*D20 FC/MC62D 24 1630 47.5 35.8 14.25 12.00
YHJF60S41S1
T*(8,L)X*C20 FC/MC62D 21
1 835 44.0 27.0
14.50 12.00
2 1665 57.0 39.5
T*9X*C20 FC/MC62D 21
1 1220 48.5 31.6
14.50 12.00
2 1595 56.5 38.5
T*9X*D20 FC/MC62D 24
1 1240 48.5 31.8
14.50 12.00
2 1645 56.5 39.0
Y*(8,L)C*C20 FC/MC62D 21
1 1015 46.0 29.2
14.50 12.00
2 1615 56.5 38.5
(Y*9C/T*9V)*C20 FC/MC62D 21
1 1040 46.5 29.4
14.50 12.00
2 1655 56.0 38.5
(Y*9C/T*9V)*D20 FC/MC62D 24
1 1085 47.0 29.8
14.50 12.00
2 1630 56.0 38.5
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)
UNIT
MODEL
FURNACE
MODEL
COIL
MODEL
1
WSTAGE
COOLING
RATED
CFM
Net MBH
SEER EER
TOTAL SENS.
14.5 SEER HP WITH VARIABLE SPEED FURNACES
2