York YHJF18 THRU 60 Heat Pump User Manual


 
510667-YTG-B-0509
24 Johnson Controls Unitary Products
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJF42S41S1
EVAPORATOR COIL MODEL NO AHX60
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1200 1400 1600
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 45.3 4.1 2.8 45.0 4.1 2.7 44.6 4.2 2.6
70 45.1 3.8 3.0 44.9 3.8 2.9 44.6 3.9 2.8
80 44.9 3.5 3.3 44.8 3.6 3.1 44.7 3.6 3.0
47
60 41.3 4.1 2.5 41.2 4.1 2.5 41.1 4.1 2.4
70 40.7 3.6 2.8 40.7 3.7 2.7 40.7 3.7 2.6
80 40.0 3.3 3.1 40.2 3.3 3.0 40.3 3.4 2.9
40
60 38.2 3.8 2.5 38.4 3.9 2.4 38.5 3.9 2.3
70 37.4 3.4 2.8 37.7 3.5 2.7 38.1 3.5 2.6
80 36.6 3.1 3.0 37.1 3.1 3.0 37.7 3.2 2.9
30
60 33.3 3.4 2.4 33.4 3.4 2.4 33.5 3.4 2.3
70 32.7 3.0 2.7 32.8 3.1 2.6 32.9 3.1 2.5
80 32.0 2.7 3.0 32.2 2.8 2.9 32.3 2.8 2.8
17
60 26.7 2.9 2.2 26.9 2.9 2.2 27.2 2.8 2.2
70 25.2 2.5 2.5 20.9 2.5 2.4 26.7 2.5 2.5
80 23.6 2.1 2.8 14.9 2.2 2.7 26.3 2.3 2.7
10
60 22.8 2.5 2.3 23.3 2.5 2.2 23.8 2.5 2.2
70 22.9 2.2 2.6 23.2 2.3 2.5 23.6 2.3 2.4
80 22.9 2.1 2.8 23.1 2.1 2.8 23.3 2.1 2.7
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil MBH KW COP
F6FP060 1.01 1.01 1.00
MV20D FC/MC62D 1.00 1.01 1.00
Furnace Coil MBH KW COP
T*(8,L)X*C16 FC/MC62D 1.00 1.02 0.99
T*(8,L)X*C20 FC/MC62D 1.01 1.02 0.99
T*9X*C16 FC/MC62D 1.01 1.00 1.02
T*9X*C20 FC/MC62D 1.00 1.01 1.00
T*9X*D20 FC/MC62D 1.00 1.01 1.00
Y*(8,L)C*C20 FC/MC62D 1.01 1.00 1.01
(Y*9C/T*9V)*C16 FC/MC62D 1.02 0.97 1.06
(Y*9C/T*9V)*C20 FC/MC62D 1.01 0.98 1.04
(Y*9C/T*9V)*D20 FC/MC62D 1.01 0.99 1.03