510667-YTG-A-0409
Johnson Controls Unitary Products 7
\
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the
total electric power input during the same period.
— = Not Applicable.
HEATING PERFORMANCE - With Air Handler
UNIT
MODEL*
AIR
HANDLER
COIL
1
MODEL
ARI HEATING
2
47F17F HSPF
MBH COP KW MBH COP KW STD
14.5 SEER HP WITH MV - VARIABLE SPEED
YHJF18S41S1
MV12B FC/MC35B 18.0 3.76 1.40 11.0 2.48 1.30 8.50
MV12B FC/MC43B 18.0 3.90 1.35 10.9 2.56 1.25 8.50
YHJF24S41S1
MV12B FC/MC35B 22.2 3.68 1.77 14.9 2.46 1.77 8.50
MV12B FC/MC43B 22.2 3.82 1.70 14.9 2.54 1.72 8.50
YHJF30S41S1
MV12B FC/MC43B 30.0 3.88 2.27 18.8 2.68 2.06 9.00
MV16C FC/MC43C 30.0 3.92 2.24 18.8 2.70 2.04 9.00
YHJF36S41S1
MV12B FC/MC43B 36.0 3.74 2.82 24.4 2.52 2.84 8.20
MV16C FC/MC43C 36.0 3.74 2.82 24.2 2.52 2.81 9.00
YHJF42S41S1 MV20D FC/MC62D 40.5 4.02 2.95 26.0 2.76 2.76 9.00
YHJF48S41S1 MV20D FC/MC62D 48.0 3.82 3.68 31.8 2.60 3.58 9.00
14.5 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
YHJF18S41S1 AV*36 – 18.0 3.98 1.33 10.8 2.62 1.21 8.50
YHJF24S41S1 AV*36 – 22.0 3.70 1.74 14.8 2.50 1.73 8.50
YHJF30S41S1 AV*36 – 29.8 3.98 2.19 18.6 2.74 1.99 9.00
YHJF36S41S1 AV*36 – 36.0 3.78 2.79 24.2 2.54 2.79 9.00
14.5 SEER HP WITH AHP / SHP / AHX / F*FP
YHJF18S41S1 AHX30 – 18.0 3.88 1.36 10.9 2.52 1.27 8.50
YHJF24S41S1
AHX30 – 22.23.641.7913.72.421.668.50
F6FP030 – 22.23.641.7915.12.421.838.20
F6FP036 – 22.23.681.7715.02.461.798.50
AHX36 – 22.43.701.7715.12.461.808.50
YHJF30S41S1
AHX36 – 30.04.002.2018.72.761.999.00
F6FP042 – 30.04.002.2018.72.761.999.00
YHJF36S41S1
AHX36 – 36.03.822.7624.22.562.779.00
AHX42 – 36.03.842.7522.22.562.549.00
F6FP042 – 36.03.882.7224.42.602.759.00
YHJF42S41S1
AHX60 – 40.54.002.9726.02.742.789.00
F6FP060 – 41.04.042.9726.22.742.809.00
YHJF48S41S1
AHX60 – 48.03.823.6831.62.603.569.00
F6FP060 – 48.03.823.6831.62.603.569.00
See notes below.
HEATING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR
HANDLER
COIL
1
MODEL
HEATING
2
STAGE
RATED
CFM
NET MBH
HSPF COP @ 47
47 OD 17 OD
14.5 SEER HP WITH MV - VARIABLE SPEED
YHJF60S41S1 MV20D FC/MC62D
1 1160 43.0 – – –
2 1855 57.0 40.5 9.00 3.66
2 1160 54.9 39.0 8.85 3.04
14.5 SEER HP WITH AHX
YHJF60S41S1 AHX60 –
1 1160 43.1 – – –
2 1855 58.0 40.0 9.00 3.72
2 1170 57.5 40.0 8.90 3.24
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. Rated CFM same as for cooling.
2. Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no
supplemental electric heat operation.