Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJF48S41S1
EVAPORATOR COIL MODEL NO F6FP060
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1400 1600 1800
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 62.2 4.3 3.7 62.7 4.5 3.5 63.2 4.6 3.3
70 60.9 3.8 4.2 61.2 3.9 4.0 61.6 4.1 3.8
80 59.5 3.3 4.8 59.8 3.5 4.5 60.0 3.6 4.2
47
60 53.1 3.6 3.8 53.1 3.7 3.6 53.1 3.8 3.4
70 52.0 3.2 4.3 52.0 3.2 4.1 52.1 3.3 3.9
80 50.9 2.8 4.8 51.0 2.9 4.6 51.0 2.9 4.5
40
60 47.9 3.2 3.8 47.8 3.3 3.6 47.8 3.4 3.4
70 47.2 2.8 4.4 47.0 2.9 4.2 46.9 3.0 3.9
80 46.5 2.5 5.0 46.2 2.6 4.7 45.9 2.6 4.4
30
60 40.1 2.9 3.6 40.2 2.9 3.5 40.3 2.9 3.3
70 38.9 2.7 3.8 39.3 2.7 3.8 39.6 2.6 3.7
80 37.8 2.5 4.0 38.3 2.4 4.0 38.8 2.4 4.1
17
60 30.2 2.6 2.8 31.3 2.8 2.8 32.4 2.9 2.7
70 28.7 2.4 3.0 29.5 2.4 3.0 30.3 2.5 2.9
80 27.3 2.2 3.2 27.7 2.2 3.2 28.1 2.2 3.1
10
60 25.2 2.4 2.6 24.8 2.3 2.5 24.4 2.3 2.5
70 24.5 2.1 2.9 25.3 2.1 3.0 26.1 2.0 3.2
80 23.8 1.9 3.1 25.7 1.8 3.5 27.7 1.8 3.9
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil MBH KW COP
AHX60 1.00 0.99 1.01
MV20D FC/MC62D 1.00 0.99 1.01
Variable Speed
Furnace
Coil MBH KW COP
T*(8,L)X*C16 FC/MC62D 1.00 0.98 1.02
T*(8,L)X*C20 FC/MC62D 1.00 0.99 1.01
T*9X*C16 FC/MC62D 1.00 0.98 1.02
T*9X*C20 FC/MC62D 1.00 0.99 1.01
T*9X*D20 FC/MC62D 1.00 0.98 1.02
Y*(8,L)(C,V)*C16 FC/MC62D 1.00 0.98 1.02
Y*(8,L)(C,V)*C20 FC/MC62D 1.00 0.98 1.02
Y*9(C,V)*C16 FC/MC62D 1.00 0.97 1.03
Y*9(C,V)*C20 FC/MC62D 1.00 0.96 1.04
Y*9(C,V)*D20 FC/MC62D 1.00 0.97 1.03