Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJF18S41S1
EVAPORATOR COIL MODEL NO AHX30
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
450 600 750
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 21.1 4.1 1.3 22.2 4.5 1.2 23.3 4.9 1.1
70 20.5 3.6 1.5 21.6 4.0 1.4 22.6 4.3 1.3
80 19.9 3.2 1.6 20.9 3.5 1.5 21.9 3.9 1.4
47
60 18.6 3.8 1.3 19.2 4.0 1.2 19.8 4.2 1.1
70 17.7 3.3 1.4 18.4 3.5 1.3 19.1 3.7 1.2
80 16.8 2.8 1.6 17.6 3.1 1.5 18.4 3.3 1.4
40
60 16.7 3.4 1.3 17.3 3.6 1.2 17.9 3.8 1.1
70 16.1 3.0 1.4 16.8 3.2 1.3 17.4 3.4 1.2
80 15.6 2.7 1.5 16.3 2.9 1.4 17.0 3.1 1.3
30
60 14.6 3.1 1.2 15.1 3.2 1.2 15.5 3.4 1.1
70 14.2 2.7 1.4 14.6 2.9 1.3 15.0 3.0 1.2
80 13.7 2.4 1.5 14.1 2.5 1.4 14.4 2.6 1.3
17
60 11.7 2.6 1.2 12.0 2.6 1.1 12.3 2.7 1.1
70 11.2 2.2 1.3 11.6 2.3 1.2 11.9 2.4 1.2
80 10.8 2.0 1.5 11.1 2.0 1.4 11.5 2.1 1.3
10
60 10.1 2.3 1.1 10.3 2.3 1.1 10.4 2.3 1.0
70 9.6 1.9 1.3 9.9 2.0 1.2 10.2 2.1 1.2
80 9.1 1.7 1.4 9.5 1.8 1.4 9.9 1.9 1.3
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil MBH KW COP
AV*36 1.00 1.03 0.97
MV12B FC/MC35B 1.00 0.97 1.03
MV12B FC/MC43B 1.00 1.01 0.99
Variable Speed
Furnace
Coil MBH KW COP
T*(8,L)X*A12 FC/MC/PC32A 0.99 0.99 1.00
Y*(8,L)(C,V)*A12 FC/MC/PC32A 1.00 0.97 1.03
Y*(8,L)(C,V)*B12 FC/MC/PC35B 1.00 0.99 1.01
Y*(8,L)(C,V)*C16 FC/MC/PC35C 1.00 0.98 1.02
Y*9(C,V)*B12 FC/MC/PC35B 1.00 0.98 1.02
Y*9(C,V)*C16 FC/MC/PC35C 1.00 0.99 1.01
Y*(8,L)(C,V)*A12 FC/MC/PC37A 1.00 1.01 0.99
Y*(8,L)(C,V)*B12 FC/MC/PC43B 1.00 0.98 1.02