4 Johnson Controls Unitary Products
— = Not applicable.
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
STAGE
COOLING
MODEL W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
14.5 SEER HP WITH MV - VARIABLE SPEED
YHJF18S41S1
MV12B 17 FC/MC35B – 600 18.0 13.0 15.00 12.50
MV12B 17 FC/MC43B – 600 18.0 13.3 15.00 12.50
YHJF24S41S1
MV12B 17 FC/MC35B – 800 22.8 17.2 15.00 12.50
MV12B 17 FC/MC43B – 800 23.4 18.0 15.00 12.50
YHJF30S41S1
MV12B 17 FC/MC43B – 1000 29.0 21.6 15.00 12.50
MV16C 21 FC/MC43C – 1000 29.0 21.6 15.00 12.50
YHJF36S41S1
MV12B 17 FC/MC43B – 1225 35.4 26.6 14.35 12.00
MV16C 21 FC/MC43C – 1200 35.2 26.4 14.50 12.00
YHJF42S41S1 MV20D 24 FC/MC62D – 1400 40.0 30.8 14.50 12.00
YHJF48S41S1 MV20D 24 FC/MC62D – 1630 48.0 36.2 15.00 12.50
YHJF60S41S1 MV20D 24 FC/MC62D
1 1160 48.0 31.0
14.50
21.55
2 1855 57.0 40.5 12.00
14.5 SEER HP WITH AV / SV / F*FV - VARIABLE SPEED
YHJF18S41S1 AV*36 21 – – 630 18.0 13.3 15.00 12.50
YHJF24S41S1 AV*36 21 – – 725 22.8 16.8 15.00 12.50
YHJF30S41S1 AV*36 21 – – 960 29.2 21.8 15.00 12.50
YHJF36S41S1 AV*36 21 – – 1190 35.4 26.4 14.50 12.00
14.5 SEER HP WITH AHP / SHP / AHX / F*FP
YHJF18S41S1 AHX30 17 – – 640 18.0 13.3 15.00 12.50
YHJF24S41S1
AHX30 17 – – 800 22.8 17.1 15.00 12.50
F6FP030 17 – – 850 22.8 17.3 14.50 12.00
F6FP036 21 – – 855 22.8 17.4 15.00 12.50
AHX36 21 – – 820 23.0 17.4 15.00 12.50
YHJF30S41S1
AHX36 21 – – 1030 29.4 22.2 15.00 12.50
F6FP042 21 – – 1065 29.4 22.2 15.00 12.50
YHJF36S41S1
AHX36 21 – – 1210 35.4 26.6 14.50 12.00
AHX42 21 – – 1190 35.8 26.8 15.00 12.50
F6FP042 24 – – 1290 36.0 27.6 15.00 12.50
YHJF42S41S1
AHX60 24 – – 1355 40.0 30.2 14.50 12.00
F6FP060 24 – – 1475 40.5 31.4 14.50 12.00
YHJF48S41S1
AHX60 24 – – 1570 48.0 35.6 15.00 12.50
F6FP060 24 – – 1570 48.0 35.6 15.00 12.50
YHJF60S41S1 AHX60 24
– 1 1160 47.5 30.5
14.50
21.20
– 2 1855 57.0 40.5 12.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.