York YHJF18 Air Conditioner User Manual


 
Subject to change without notice. Printed in U.S.A. 510667-YTG-A-0409
Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: Nothing
Johnson Controls Unitary Products
5005 York Drive
Norman, OK 73069
Multipliers for determining the performance with other indoor sections.
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO YHJF60S41S1
EVAPORATOR COIL MODEL NO AHX60
AIR TEMP.
ENTERING
OUTDOOR UNIT
AIR TEMP.
ENTERING
INDOOR COIL
ID CFM
1600 1800 2000
MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P.
60
60 70.70 4.28 4.25 71.76 4.41 4.11 72.83 4.54 3.97
70 69.78 3.85 4.72 70.63 3.95 4.57 71.49 4.07 4.41
80 68.86 3.48 5.19 69.51 3.58 5.03 70.15 3.67 4.86
47
60 61.77 3.89 4.05 62.15 3.97 3.92 62.54 4.05 3.78
70 60.84 3.47 4.53 61.18 3.55 4.39 61.52 3.62 4.23
80 59.90 3.13 5.01 60.20 3.19 4.86 60.50 3.27 4.69
40
60 56.20 3.64 3.93 56.47 3.70 3.80 56.74 3.76 3.69
70 55.47 3.24 4.42 55.62 3.30 4.27 55.76 3.35 4.13
80 54.75 2.92 4.90 54.77 2.96 4.75 54.79 3.02 4.57
30
60 49.33 3.30 3.78 49.52 3.33 3.70 49.72 3.34 3.61
70 47.84 2.83 4.36 47.68 2.87 4.21 47.52 2.90 4.06
80 46.36 2.45 4.94 45.84 2.49 4.71 45.31 2.53 4.51
17
60 40.18 2.78 3.64 37.45 2.80 3.50 34.72 2.80 3.40
70 40.02 2.47 4.14 38.68 2.60 4.00 37.36 2.50 3.91
80 39.86 2.23 4.65 39.91 2.25 4.53 39.99 2.27 4.42
10
60 35.02 2.49 3.52 35.29 2.51 3.45 35.54 2.53 3.38
70 33.76 2.16 3.98 34.56 2.22 3.90 35.35 2.27 3.82
80 32.50 1.89 4.44 33.83 1.97 4.34 35.15 2.06 4.26
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil MBH KW COP
MV20D FC/MC62D 0.99 1.00 0.99
Variable Speed
Furnace
Coil MBH KW COP
T*(8,L)X*C20 FC/MC62D 0.97 0.89 1.10
T*9X*C20 FC/MC62D 1.00 1.01 1.00
T*9X*D20 FC/MC62D 1.00 1.02 0.99
Y*(8,L)(C,V)*C20 FC/MC62D 0.99 0.95 1.04
Y*9(C,V)*C20 FC/MC62D 0.99 0.96 1.04
Y*9(C,V)*D20 FC/MC62D 1.00 0.97 1.03