York H*RC018 THRU 060 Air Conditioner User Manual


 
036-21137-004 Rev. C (0505)
6 Unitary Products Group
- = Not applicable.
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL
1
MODEL
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
WITH TXV
3
EER
TOTAL SENS.
1 PH 12 SEER AC WITH N1AH / G2FD
H2RC018S06 N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 600 19.6 13.2 12.50 12.50 11.60
H2RC024S06
N1AHB0806 2,5,8,10 17 G2FD024(S,H)17 750 23.6 16.9 12.00 12.00 11.00
N1AHB0806 2,5,8,10 17 G2FD030(S,H)17 750 24.0 17.3 12.00 12.00 11.10
H2RC030S06
N1AHB1206 2,5,8,10 17 G2FD030(S,H)17 1000 30.0 21.3 12.00 12.00 11.00
N1AHB1206 2,5,8,10 17 G2FD036(S,H)17 1000 30.6 21.8 12.25 12.25 11.20
H2RC036S06
N1AHB1206 5,8,10,15,19 17 G2FD036(S,H)17 1200 33.8 23.6 11.50 11.50 10.70
N1AHB1206 5,8,10,15,19 17 G2FD046(S,H)17 1200 35.0 24.4 12.00 12.00 10.90
H2RC042S06
N1AHC1606 5,8,10,15,20 21 G2FD042(S,H)21 1400 41.0 29.3 12.00 10.50
N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1400 42.5 30.6 12.00 10.75
H2RC048S06
N1AHC1606 5,8,10,15,20 21 G2FD048(S,H)21 1575 46.5 36.0 12.20 12.20 10.90
N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1575 48.0 36.4 12.50 12.50 11.10
N1AHD2006 8,10,15,20,25,30 24 G2FD061H24 1575 48.5 34.5 12.50 12.50 11.20
H3RC060S06
N1AHD2006 8,10,15,20,25,30 24 G2FD060(S,H)24 1800 57.5 42.6 12.00 10.40
N1AHD2006 8,10,15,20,25,30 24 G2FD061H24 1850 58.0 43.2 12.00 10.45
3 PH 12 SEER AC WITH N1AH / G2FD
H1RC036S(25,46)
N1AHB1246 5,8,10,15,18 17 G2FD036(S,H)17 1255 33.6 24.9 12.00 10.65
N1AHB1246 5,8,10,15,18 17 G2FD046(S,H)17 1250 34.8 25.8 12.00 10.95
N1AHC1646 5,8,10,15,18 21 G2FD048(S,H)21 1600 45.5 33.7 12.20 11.20
H1RC048S(25,46)
N1AHD2046 8,10,15,20,25,30 24 G2FD060(S,H)24 1620 47.0 34.8 12.50 11.45
N1AHD2046 8,10,15,20,25,30 24 G2FD061H24 1600 47.5 35.2 12.50 11.50
H1RC060S(25,46)
N1AHD2046 8,10,15,20,25,30 24 G2FD060(S,H)24(T) 1800 56.5 43.4 12.00 10.10
N1AHD2046 8,10,15,20,25,30 24 G2FD061H24 1800 56.5 43.8 12.00 10.15
1 PH 12 SEER / N1VS - VARIABLE SPEED
H2RC018S06 N1VSB12 10,15,18 17 G2FD024(S,H)17 650 20.2 13.2 13.75 13.75 12.80
H2RC024S06
N1VSB12 10,15,18 17 G2FD024(S,H)17 725 24.2 16.9 13.35 13.35 12.15
N1VSB12 10,15,18 17 G2FD036(S,H)17 775 25.2 17.8 13.50 13.50 12.50
H2RC030S06
N1VSB12 10,15,18 17 G2FD036(S,H)17 1000 31.0 21.9 13.25 13.25 12.15
N1VSB12 10,15,18 17 G2FD046(S,H)17 1000 32.0 22.3 13.75 13.75 12.55
N1VSB12 10,15,18 17 G2FD046(S,H)17 1000 32.0 22.3 13.75 13.75 12.55
H2RC036S06
N1VSB12 10,15,18 17 G2FD036(S,H)17 1200 34.8 23.6 12.40 12.40 11.35
N1VSB12 10,15,18 17 G2FD046(S,H)17 1210 35.8 24.4 13.00 13.00 11.65
N1VSC16 10,15,18 21 G2FD048(S,H)21 1155 36.8 25.1 13.40 13.40 12.20
H2RC042S06
N1VSC16 10,15,18 21 G2FD048(S,H)21 1400 43.0 30.6 13.00 11.55
N1VSC16 10,15,18 21 G2FD048(S,H)21 1590 47.0 30.6 12.80 11.40
H2RC048S06
N1VSC16 10,15,18 21 G2FD048(S,H)21 1590 47.0 34.9 12.80 12.80 11.40
N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1560 48.5 36.0 13.25 13.25 11.75
N1VSD20 10,15,18,30 24 G2FD061H24 1560 49.0 36.4 13.30 13.30 11.90
H3RC060S06
N1VSD20 10,15,18,30 24 G2FD060(S,H)24 1780 56.0 42.3 12.10 10.25
N1VSD20 10,15,18,30 24 G2FD061H24 1780 56.5 42.7 12.25 10.40
1 PH 12 SEER AC / F2RP / RC / FC
4
,
5
H2RC018S06
F2RC/F2FC024 5,8,10 18 600 20.0 13.2 12.50 12.50 11.70
F2RP/F2FP024 5,8,10 18 600 20.0 13.2 12.50 12.50 11.70
H2RC024S06
F2RC/F2FC024 5,8,10 18 750 23.4 17.5 11.50 11.50 10.85
F2RC/F2FC030 5,8,10,15 18 750 23.4 17.5 11.50 11.50 10.85
F2RP/F2FP024 5,8,10 18 750 23.6 17.5 12.00 12.00 10.90
F2RP/F2FP030 5,8,10,15 18 750 24.0 17.9 12.00 12.00 11.10
H2RC030S06
F2RC/F2FC030 5,8,10,15 18 1000 29.8 21.5 12.00 12.00 11.00
F2RC/F2FC036 5,8,10,15 21 1000 31.0 22.4 12.25 12.25 11.30
F2RP/F2FP030 5,8,10,15 18 1000 30.2 22.9 12.00 12.00 11.15
F2RP/F2FP036 5,8,10,15,19 21 1000 30.2 23.5 12.00 12.00 11.15
H2RC036S06
F2RC/F2FC036 5,8,10,15 21 1200 34.6 26.2 12.00 12.00 10.85
F2RP/F2FP036 5,8,10,15,19 21 1200 34.6 26.2 12.00 12.00 10.85
F2RP/F2FP042 5,8,10,15 21 1200 34.8 26.3 11.60 11.60 10.70
F2FP048 5,8,10,15,20,25 24 1200 35.4 26.7 12.00 12.00 10.90
H2RC042S06
F2RP/F2FP042 5,8,10,15 21 1400 40.5 28.9 11.80 10.35
F2FP048 5,8,10,15,20,25 24 1400 42.5 30.5 12.00 10.55
H2RC048S06
F2FP048 5,8,10,15,20,25 24 1565 46.5 34.9 11.40 11.40 10.75
F2FP060 5,8,10,15,20,25 24 1575 48.0 35.9 11.50 11.50 10.70
F2FV060 8,10,15,20,25 24 1560 48.5 35.9 13.20 13.20 11.70
H3RC060S06
F2FP060 5,8,10,15,20,25 24 1800 56.0 42.0 12.00 10.00
F2FV060 8,10,15,20,25 24 1780 56.0 42.3 12.10 10.30
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.
3. TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC
. models. All ratings remain the same.
5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.