York H*RC018 THRU 060 Air Conditioner User Manual


 
036-21137-004 Rev. C (0505)
Unitary Products Group 17
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree belowthe listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO. H2RC036S06
INDOOR COIL MODEL NO. G1FA048S21
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM 1000 1200 1400
ID DB (°F) 85 80 75 85 80 75 85 80 75
ID WB (°F) 72 67 63 72 67 63 72 67 63
75
T.C. 36.7 34.3 32.3 36.9 34.9 32.8 37.2 35.4 33.2
S.C. 23.2 22.8 22.5 24.3 24.2 23.9 25.4 25.6 25.4
KW 2.31 2.30 2.27 2.33 2.30 2.28 2.34 2.31 2.30
85
T.C. 35.3 33.1 30.9 35.7 33.7 31.4 36.2 34.2 31.9
S.C. 23.2 22.6 21.9 24.8 24.3 23.6 26.3 26.0 25.3
KW 2.51 2.48 2.45 2.53 2.50 2.47 2.54 2.51 2.48
95
T.C. 34.0 31.9 29.6 34.5 33.6 30.0 35.1 33.0 30.5
S.C. 23.3 22.4 21.3 25.3 23.4 23.3 27.3 26.4 25.2
KW 2.71 2.67 2.64 2.73 2.73 2.66 2.74 2.71 2.67
105
T.C. 31.8 29.5 27.2 32.3 30.0 27.6 32.9 30.5 28.0
S.C. 22.6 21.6 20.5 24.8 23.7 22.5 26.9 25.8 24.5
KW 2.93 2.88 2.82 2.94 2.90 2.85 2.96 2.92 2.87
115
T.C. 29.6 27.2 24.8 30.1 27.6 25.1 30.6 28.0 25.4
S.C. 22.0 20.8 19.7 24.3 23.0 21.8 26.6 25.2 23.9
KW 3.15 3.09 3.01 3.16 3.11 3.04 3.18 3.13 3.07
125
T.C. 27.3 24.8 22.4 27.8 25.2 22.6 28.4 25.5 22.9
S.C. 21.4 20.0 19.0 23.8 22.3 21.1 26.2 24.6 23.2
KW 3.36 3.29 3.19 3.38 3.31 3.23 3.39 3.33 3.26
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
F2RC/F2FC036 1.02 1.04 1.00
F2RP/F2FP036 1.02 1.03 1.00
F2RP/F2FP042 1.02 1.04 1.02
F2FP048 1.04 1.06 1.02
N1VSB12 G2FD036(S,H)17 1.02 1.03 0.96
N1VSB12 G2FD046(S,H)17 1.05 1.08 0.97
N1VSC16 G2FD048(S,H)21 1.08 1.11 0.95
N1AHB1206 G2FD036(S,H)17 0.99 0.94 0.99
N1AHB1206 G2FD046(S,H)17 1.03 0.97 1.01
G1FA036S17,21 0.97 0.91 0.99
G1FA036S14 0.99 0.93 1.00
G1FA048S17 1.03 0.97 1.01
G1HD036 1.00 0.94 1.00
G1HD048 1.04 0.98 1.01
G1NA048S21D 1.03 0.99 1.01
G1NA036S17L 1.03 0.99 1.01
G1UA036S17,21 0.97 0.91 0.99
G1UA036S14 0.99 0.93 1.00
G1UA048S17 1.03 0.97 1.01
G1UA048S21 1.00 1.00 1.00
G2FD035(S,H)14 0.97 0.91 0.99
G2FD036(S,H)17 0.99 0.94 0.99
G2FD036(S,H)21 1.01 0.95 1.00
G2FD042(S,H)21 1.02 0.96 1.01
G2FD046(S,H)17 1.03 0.97 1.01
G2FD048(S,H)21,24 1.06 1.00 1.02
Variable Speed
Furnace
Coil
T.C. S.C. KW
P1DUA12V G1FA036S14 0.99 0.94 0.97
P1DUA12V G2FD035(S,H)14 0.98 0.92 0.97
P1DUB16V G1FA036S17 0.98 0.93 0.94
P1DUB16V G2FD036(S,H)17 1.01 0.96 0.95
P1DUC20V G1FA036S21 0.99 0.94 0.94
P1DUC20V G2FD036(S,H)21 1.02 0.97 0.94
P1XDB12V G2FD036(S,H)17 1.01 0.97 0.97
P1XUB12V G1FA036S17 0.98 0.92 0.97
P1XUB12V G2FD036(S,H)17 1.00 0.94 0.97
P1XUC16V G1FA036S21 0.98 0.93 0.94
P1XUC16V G2FD036(S,H)21 1.02 0.97 0.96
P1XUC20V G1FA048S21 1.02 1.02 0.94
P1XUC20V G2FD042(S,H)21 1.04 0.98 0.95
P1XUD20V G2FD048(S,H)24 1.07 1.01 0.98