York H*RC018 THRU 060 Air Conditioner User Manual


 
036-21137-004 Rev. C (0505)
Unitary Products Group 11
H2RC048S06
P1DUC20V/PV8C20****UH G1FA048S21 21 1610 46.5 34.9 12.10 11.15
P1DUC20V/PV8C20****UH G2FD048(S,H)21 21 1610 46.5 34.9 12.25 11.05
P1XDD20V G2FD048(S,H)24 24 1610 47.0 35.4 12.40 11.00
P1XUC16V G1FA048S21 21 1480 46.0 34.4 12.10 10.90
P1XUC16V G2FD048(S,H)21 21 1480 46.0 34.4 12.30 10.80
P1XUC20V G1FA048S21 21 1590 46.5 34.9 12.10 11.10
P1XUC20V G2FD048(S,H)21 21 1590 46.5 34.9 12.25 11.00
P1XUD20V G1FA060S24 24 1560 48.5 36.5 13.00 11.45
P1XUD20V G2FD048(S,H)24 24 1560 47.0 35.4 12.50 11.20
P1XUD20V G2FD060(S,H)24 24 1560 48.5 36.5 13.00 11.45
H1RC048S(25,46)
P1DUC20V/PV8C20****UH G1FA048S21 21 1610 45.5 33.7 12.20 11.20
P1DUC20V/PV8C20****UH G2FD048(S,H)21 21 1610 45.5 33.7 12.25 11.40
P1XUC16V G1FA048S21 21 1480 45.0 33.2 12.20 10.95
P1XUC16V G2FD048(S,H)21 21 1480 45.0 33.2 12.30 11.10
P1XUC20V G1FA048S21 21 1590 45.5 33.7 12.10 11.15
P1XUC20V G2FD048(S,H)21 21 1590 45.5 33.7 12.25 11.35
P1XUD20V G1FA060S24 24 1620 47.0 34.8 12.75 11.65
P1XUD20V G2FD048(S,H)24 24 1620 45.5 33.7 12.25 11.30
P1XUD20V G2FD060(S,H)24 24 1620 47.0 34.8 12.75 11.65
H4RC060S06
P*DUC20V G1FA/G1UA060S21(T) 21 1730 56.0 42.8 12.10 10.20
P*DUC20V G2FD060(S,H)24(T) 24 1730 56.0 42.8 12.10 10.20
P*DUC20V G2FD061H24 24 1730 56.5 43.2 12.10 10.30
P1XUC20V G1FA/G1UA060S21(T) 21 1640 56.0 41.8 12.10 10.10
P1XUC20V G2FD060(S,H)24(T) 24 1640 56.0 41.8 12.10 10.10
P1XUC20V G2FD061H24 24 1640 56.5 42.0 12.10 10.25
P1XUD20V G1FA/G1UA060S24(T) 24 1620 56.0 41.6 12.10 10.30
P1XUD20V G2FD060(S,H)24(T) 24 1620 56.0 41.6 12.10 10.30
P1XUD20V G2FD061H24 24 1620 56.5 41.9 12.25 10.40
P1XDC20V G2FD060(S,H)24(T) 24 1575 55.5 40.9 12.10 10.20
P1XDC20V G2FD061H24 24 1575 56.0 41.0 12.10 10.20
P1XDC20V G1HA60H24(T) 24 1575 55.5 40.9 12.00 10.20
P1XDC20V G1HD060 - 1575 55.0 40.2 11.75 10.10
P1XDD20V G2FD060(S,H)24(T) 24 1610 56.0 41.4 12.10 10.25
P1XDD20V G2FD061H24 24 1610 56.0 41.7 12.10 10.30
P1XDD20V G1HA60H24(T) 24 1610 56.0 41.4 12.00 10.25
P1XDD20V G1HD060 - 1610 55.0 40.6 12.00 10.15
PV8C20****UH G1FA/G1UA060S21(T) 21 1730 56.0 42.8 12.10 10.20
PV8C20****UH G2FD060(S,H)24(T) 24 1730 56.0 42.8 12.10 10.20
PV8C20****UH G2FD061H24 24 1730 56.5 43.2 12.10 10.30
H1RC060S(25,46)
P1XDD20V G2FD060(S,H)24 24 1805 57.0 42.6 11.50 10.00
P1XUC20V G1FA060S21 21 1620 57.0 42.1 12.10 10.20
P1XUD20V G1FA060S24 24 1620 57.0 42.1 12.10 10.40
P1XUD20V G2FD060(S,H)24 24 1620 57.0 42.1 12.10 10.40
P1XUD20V G2FD061
H24 24 1800 58.0 43.2 12.10 10.55
1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. TXV = Use 1TV700 Series Kit.
3. Variable speed furnaces have B.O.D (Blower on Delay) standard.
COOLING CAPACITY - With Variable Speed Furnaces
UNIT MODEL
VARIABLE SPEED
FURNACE MODEL
COIL MODEL
1
W
COOLING
RATED
CFM
NET MBH
SEER
W/O TXV
SEER
+ TXV
2
EER
TOTAL SENS.