York H5CE090 Air Conditioner User Manual


 
035-15407-002-B-0404
2 Unitary Products Group
General
................................................................................
1
Reference
............................................................................
1
Inspection
............................................................................
1
Nomenclature
......................................................................
2
INSTALLATION
Limitations
...........................................................................
3
Location
...............................................................................
3
Roof-Top Locations
......................................................
3
Ground Level Locations
...............................................
3
Rigging and Handling
..........................................................
3
Clearances
..........................................................................
4
Power and Control Wiring
...................................................
4
Power Wiring
................................................................
4
Control Wiring
..............................................................
4
Compressor
.........................................................................
4
Compressor Crankcase Heater
...........................................
4
Refrigerant Piping
................................................................
7
General Guidelines
......................................................
7
Line Sizing
....................................................................
7
Service Valves
..............................................................
7
Extending The Service Ports...............................................9
Installation ...........................................................................9
Evacuation and Charging..................................................10
START-UP
Crankcase Heater .............................................................14
Pre-Start Check.................................................................14
Initial Start-Up....................................................................14
Secure Owner’s Approval..................................................14
OPERATION
Unit Operation - 7-1/2, 10 & 12-1/2 Ton
............................
14
Safety Features
.................................................................
15
Maintenance
......................................................................
15
Cleaning Condenser Surface
.....................................
15
Lubrication
..................................................................
15
Compressor Replacement
.........................................
15
TABLES
No. Description Page
1 Unit Application Data
..................................
3
2 Physical Data
.............................................
4
3 Electrical Data
............................................
5
4 Suction Lines
..............................................
8
5 Liquid Lines
................................................
8
6 Refrigerant Line Charge
.............................
8
7 Cooling Cap's. & Power Requirements
......
9
FIGURES
No. Description Page
1 Center of Gravity........................................ 3
2 Typical Rigging........................................... 4
3 Typical Field Wiring with KES/KEU............ 5
4 Typical Field Wiring with PUC.................... 5
5 Unit Dimensions and Clearances............... 6
6 Four Point Loads........................................ 7
7 Extending the Service Ports
.......................
11
8 Charging Curve HCE090
...........................
12
9 Charging Curve HCE120
...........................
12
10 Charging Curve HCE150
...........................
13
H 4 C E 2 59 A
PRODUCT NOMENCLATURE
PRODUCT GENERATION
1 = 1st Generation
2 = 2nd Generation
3 = 3rd Generation
4 = 4th Generation
PRODUCT CATEGORY
H = Split-System Condensing Unit
PRODUCT IDENTIFIER
CE = Condensing Section
VOLTAGE CODE
25 = 208/230-3-60
46 = 460-3-60
58 = 575-3-60
NOMINAL COOLING
CAPACITY
090 = 7-1/2 Tons
120 = 10 Tons
150 = 12-1/2 Tons
FACTORY INSTALLED HEAT
A = Not Applicable
0 0
TABLE OF CONTENTS