York CZB018 THRU 060 Air Conditioner User Manual


 
246723-YTG-J-1006
6 Unitary Products Group
1 PH 13 SEER AC WITH AHP/ SHP / F*FP
CZB01811
AHP18 2,5,8 17 600 18.0 12.1 13.00 11.00
AHP24 2,5,8,10 17 600 18.0 12.3 13.00 11.00
F*FP024 5,8,10 17 600 18.0 12.1 13.00 11.00
CZB02411
AHP24 2,5,8,10 17 800 23.0 16.9 13.00 11.00
F*FP030 5,8,10,15 17 800 23.0 16.7 13.00 11.00
CZB03011
AHP30 5,8,10 17 1000 30.0 21.9 13.00 11.00
AHP36 5,8,10,15,18 17 1000 30.0 21.9 13.00 11.00
F*FP030 5,8,10,15 17 1000 29.6 21.6 13.00 11.00
F*FP036 5,8,10,15,19 21 1000 30.0 22.3 13.00 11.00
CZB03611
AHP36 5,8,10,15,18 17 1200 36.0 26.5 13.00 11.00
AHP42 5,8,10,15,18 21 1200 36.0 26.5 13.00 11.00
F*FP036 5,8,10,15,19 21 1200 36.0 26.7 13.00 11.00
F*FP042 5,8,10,15,18 21 1200 36.0 26.8 13.00 11.00
CZB04211
AHP/SHP48 5,8,10,15,20 24 1400 41.5 30.5 13.00 11.00
AHP/SHP60 5,8,10,15,20,25 24 1400 41.5 30.5 13.00 11.00
F*FP045 5,8,10,15 24 1400 41.0 30.2 13.00 11.00
F*FP048 5,8,10,15 24 1400 41.0 30.2 13.00 11.00
CZB04811
AHP/SHP48 5,8,10,15,20 24 1600 48.0 36.1 13.00 11.00
AHP/SHP60 5,8,10,15,20,25 24 1600 48.0 36.1 13.00 11.00
CZB06011 AHP/SHP60 5,8,10,15,20,25 24 1800 55.5 39.7 13.00 11.00
1 PH 13 SEER AC WITH AV / SV / F*FV VARIABLE SPEED
CZB01811 AV24 2,5,8,10 17 600 18.0 12.1 14.00 11.50
CZB02411 AV24 2,5,8,10 17 800 23.0 16.7 14.00 11.50
CZB03011 AV36 5,8,10,15,18 17 1000 30.0 21.9 14.00 11.50
CZB03611 AV36 5,8,10,15,18 17 1200 36.0 26.5 14.00 11.50
CZB04211 AV/SV48 5,8,10,15,20 24 1400 41.5 30.5 14.00 11.50
CZB04811
AV/SV48 5,8,10,15,20 24 1600 48.0 35.8 14.00 11.50
AV/SV60 5,8,10,15,20,25 24 1600 48.0 35.8 14.00 11.50
F*FV060 5,8,10,15,20,25 24 1600 48.0 36.5 13.25 11.00
CZB06011
AV/SV60 5,8,10,15,20,25 24 1800 57.0 40.8 14.00 11.50
F*FV060 5,8,10,15,20,25 24 1780 55.5 40.8 13.25 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1 MC & G*FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2 Single phase units require single phase 2HK or 4HK heaters.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL
ELECTRIC
HEAT KW
2
W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.