246723-YTG-J-1006
12 Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO. CZB02411
INDOOR COIL MODEL NO. G2FD030S17
CONDENSER
ENTERING AIR
TEMPERATURE
ID CFM
600 800 1000
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 19.2 19.4 22.0 23.0 26.2 21.5 21.2 22.1 23.8 26.5 23.8 25.7 22.3 24.6 26.8
S.C. 18.9 16.4 15.9 15.7 11.9 21.2 20.9 18.1 18.3 13.4 23.5 25.4 20.3 21.0 14.8
K.W. 1.8 1.9 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.8 1.9 1.8 1.8
75
T.C. 21.5 22.3 20.7 24.9 27.5 23.1 23.5 22.5 25.8 28.5 24.7 24.7 24.3 26.7 29.5
S.C. 21.2 18.3 14.9 15.5 12.4 22.8 21.3 17.3 17.7 13.8 24.4 24.4 19.8 19.9 15.2
K.W. 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6
85
T.C. 20.3 20.8 21.4 23.9 26.8 22.3 23.0 22.3 24.8 27.5 24.3 25.2 23.3 25.7 28.2
S.C. 20.0 17.3 15.4 15.6 12.1 22.0 21.1 17.7 18.0 13.6 23.9 24.9 20.0 20.4 15.0
K.W. 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7
95
T.C. 18.9 19.6 19.7 22.2 25.0 20.8 21.4 20.6 23.0 25.7 22.6 23.3 21.5 23.8 26.3
S.C. 18.6 16.5 14.3 14.5 11.5 20.5 19.8 16.5 16.8 12.9 22.3 23.0 18.7 19.1 14.3
K.W. 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.1 2.0 2.1 2.0 2.0
105
T.C. 17.4 18.3 18.0 20.4 23.2 19.2 19.8 18.9 21.2 23.8 21.0 21.4 19.7 22.0 24.5
S.C. 17.2 15.7 13.2 13.4 10.9 18.9 18.4 15.2 15.6 12.2 20.7 21.1 17.3 17.8 13.6
K.W. 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4
115
T.C. 16.0 17.2 16.4 18.7 21.4 17.7 18.3 17.2 19.4 22.0 19.3 19.5 17.9 20.2 22.7
S.C. 15.8 15.0 12.1 12.4 10.3 17.4 17.1 14.0 14.4 11.6 19.1 19.2 15.9 16.5 12.8
K.W. 2.8 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7 2.7
125
T.C. 14.6 15.9 14.8 17.0 19.6 16.2 16.7 15.5 17.7 20.3 17.7 17.6 16.2 18.4 21.0
S.C. 14.4 14.2 11.0 11.4 9.7 16.0 15.8 12.8 13.3 10.9 17.5 17.3 14.6 15.2 12.1
K.W. 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1 3.1
NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil
T.C. S.C. KW
MA08B FC/MC24B 1.00 1.01 1.00
MA08B FC/MC30B 1.00 1.01 1.00
MA08B G*FD036H17 1.01 1.01 1.00
MV12B MC24B 1.00 1.01 0.95
AHP24 – 1.00 1.01 1.00
AV24 – 1.00 1.00 0.95
F*FP030 – 1.00 1.00 1.00
– FC/MC/PC/UC24 1.00 1.01 1.00
– FC/MC/PC/UC30 1.00 1.01 1.00
– G*FA036S14 1.00 1.01 1.00
– G*FA036S17,21 1.00 1.00 1.00
– G*FD035H14 1.00 1.00 1.00
– G*FD036H17 1.01 1.01 1.00
– HC30 0.98 0.98 1.00
– HD24 0.98 0.98 1.00
Variable Speed
Furnace
Coil
T.C. S.C. KW
PV8*A12 FC/MC/PC24A 1.02 1.02 0.95
PV9*A12 FC/MC/PC24A 1.02 1.02 0.95
PV9*B12 FC/MC/PC24B 1.02 1.02 0.95
PV8*A12 FC/MC/PC30A 1.02 1.02 0.95
PV9*A12 FC/MC/PC30A 1.02 1.02 0.95
PV9*B12 FC/MC/PC30B 1.02 1.02 0.95
PV8*A12 HC30 0.990.990.95
PV9*A12 HC30 0.990.990.95
PV8*A12 HD24 0.990.990.95
PV9*A12 HD24 0.990.990.95