York AY012MA321 Air Conditioner User Manual


 
246814-YTG-D-0606
Unitary Products Group 5
1. G4FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
COOLING CAPACITY - With Air Handler Coils
UNIT MODEL
AIR HANDLER
COIL MODEL
1
COOLING
MODEL
ELECTRIC
2
HEAT KW
W
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
1 PH 13 SEER AC WITH MV - VARIABLE SPEED
AY018MA321
MV12B 5,8,10 17 FC/MC18B 600 18.4 12.8 14.50 12.00
MV12B 5,8,10 17 G4FD024H17T2A 600 18.4 12.8 14.50 12.00
AY024MA321
MV12B 5,8,10 17 FC/MC24B 800 24.0 17.7 14.50 12.00
MV12B 5,8,10 17 FC/MC30B 800 24.0 17.7 14.50 12.00
MV12B 5,8,10 17 FC/MC36B 800 24.0 17.7 14.50 12.00
MV12B 5,8,10 17 G4FD030H17T2A 800 24.0 17.7 14.50 12.00
MV12B 5,8,10 17 G4FD036H17T2A 800 24.0 17.7 14.50 12.00
MV16C 5,8,10,15,18,20 21 FC/MC36C 800 24.0 17.7 14.50 12.00
AY030MA321
MV12B 5,8,10 17 FC/MC36B 1000 29.2 21.4 11.70 10.40
MV12B 5,8,10 17 FC/MC42B 1000 29.4 21.6 12.00 10.40
MV12B 5,8,10 17 G4FD036H17T2A 1000 29.2 21.4 11.70 10.40
MV12B 5,8,10 17 G4FD046H17T2A 1000 29.4 21.6 12.00 10.40
MV16C 5,8,10,15,18,20 21 FC/MC36C 1000 29.4 21.6 11.70 10.40
MV16C 5,8,10,15,18,20 21 FC/MC42C 1000 29.4 21.6 11.70 10.40
MV16C 5,8,10,15,18,20 21 G4FD036H21T2A 1000 29.4 21.6 11.70 10.40
MV16C 5,8,10,15,18,20 21 G4FD042H21T2A 1000 29.4 21.6 11.70 10.40
AY036MA321
MV12B 5,8,10 17 FC/MC42B 1200 35.8 25.9 13.75 11.00
MV12B 5,8,10 17 G4FD046H17T2A 1200 35.8 25.9 13.75 11.00
MV16C 5,8,10,15,18,20 21 FC/MC42C 1200 36.0 26.1 14.00 11.50
MV16C 5,8,10,15,18,20 21 FC/MC48C 1200 36.0 26.1 14.00 11.50
MV16C 5,8,10,15,18,20 21 G4FD042H21T2A 1200 36.0 26.1 14.00 11.50
MV16C 5,8,10,15,18,20 21 G4FD048H21T2A 1200 36.0 26.1 14.00 11.50
MV20D 8,10,15,18,20,25 24 FC/MC48D 1200 36.0 26.1 14.00 11.50
MV20D 8,10,15,18,20,25 24 G4FD048H24T2A 1200 36.0 26.1 14.00 11.50
1 PH 13 SEER AC WITH AHP
AY012MA321 AHP18 2,5,8 17 430 15.5 9.9 13.50 11.00
AY018MA321
AHP18 2,5,8 17 650 18.0 12.4 13.00 11.00
AHP24 2,5,8,10 17 655 18.0 12.4 13.00 11.00
AY024MA321 AHP24 2,5,8,10 17 830 23.4 17.1 13.00 11.00
AY030MA321 AHP36 5,8,10,15,18 17 1040 28.8 21.0 10.90 9.90
AY036MA321 AHP42 5,8,10,15,18 21 1255 35.4 25.5 13.00 11.00
1 PH 13 SEER AC WITH F4FP
AY018MA321 F4FP024H06T2A 5,8,10 17 600 18.0 12.4 13.00 11.00
AY024MA321 F4FP030H06T2A 5,8,10,15 17 800 23.4 17.1 13.00 11.00
AY036MA321 F4FP042H06T2A 5,8,10,15 24 1200 35.4 25.5 13.00 11.00
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 80ºF entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95ºF outdoor ambient divided by the total electric power in watt-hours at those conditions
.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BUT’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.