York AY012MA321 Air Conditioner User Manual


 
246814-YTG-D-0606
14 Unitary Products Group
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
AIR CONDITIONER MODEL NO.
AY030MA321
INDOOR COIL MODEL NO.
G2FD036S17
CONDENSER
ENTERING AIR
TEMPERATUR
ID CFM
800 1000 1200
ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80
ID WB (°F) 57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C. 27.2 30.0 29.5 32.7 35.7 28.7 30.4 30.1 33.0 35.7 30.1 30.7 30.6 33.4 35.6
S.C. 25.6 24.4 20.7 20.5 16.4 27.1 26.7 23.0 22.6 17.8 28.6 29.0 25.4 24.7 19.2
KW 1.9 1.9 1.9 1.9 2.0 1.9 1.9 1.9 1.9 2.0 1.9 1.9 1.9 2.0 2.0
75
T.C. 26.6 28.8 28.4 31.4 34.3 28.0 29.2 28.8 31.6 34.3 29.3 29.6 29.3 31.8 34.3
S.C. 25.1 23.7 20.0 20.0 15.9 16.4 25.8 22.1 22.1 17.2 27.8 28.0 24.2 24.1 18.5
KW 2.1 2.1 2.1 2.2 2.2 2.1 2.1 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2
85
T.C. 26.1 27.6 27.2 30.1 32.9 27.2 28.1 27.6 30.2 33.0 28.4 28.5 28.0 30.3 33.0
S.C. 24.5 22.9 19.2 19.5 15.5 25.7 25.0 21.1 21.5 16.6 27.0 27.1 23.0 23.6 17.8
KW 2.3 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4 2.4
95
T.C. 25.5 26.4 26.1 28.9 31.5 26.5 26.9 26.4 28.8 31.6 27.5 27.4 26.6 28.7 31.7
S.C. 23.9 22.2 18.5 19.0 15.0 25.0 24.2 20.2 21.0 16.0 26.2 26.1 21.8 23.0 17.1
KW 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.6 2.7 2.6 2.6 2.6 2.6 2.7
105
T.C. 24.6 25.3 25.0 27.5 30.2 25.5 25.8 25.3 27.5 30.2 26.4 26.3 25.5 27.5 30.1
S.C. 23.0 21.8 18.1 18.4 14.6 24.1 23.4 19.8 20.5 15.7 25.1 25.0 21.6 22.6 16.8
KW 2.8 2.8 2.8 2.9 2.9 2.8 2.9 2.8 2.9 2.9 2.9 2.9 2.9 2.9 3.0
115
T.C. 23.7 24.2 24.0 26.3 28.9 24.5 24.7 24.2 26.3 28.8 25.3 25.1 24.4 26.3 28.6
S.C. 22.2 21.4 17.6 17.9 14.3 23.2 22.6 19.5 20.1 15.4 24.1 23.9 21.4 22.2 16.4
KW 3.1 3.1 3.1 3.1 3.2 3.1 3.1 3.1 3.2 3.2 3.2 3.2 3.2 3.2 3.2
125
T.C. 22.8 23.2 23.0 25.0 27.7 23.5 23.6 23.2 25.1 27.4 24.3 23.9 23.4 25.1 27.1
S.C. 21.4 21.0 17.2 17.4 14.0 22.3 21.9 19.2 19.6 15.0 23.1 22.8 21.3 21.8 16.1
KW 3.3 3.3 3.3 3.4 3.5 3.4 3.4 3.4 3.4 3.5 3.4 3.4 3.4 3.4 3.5
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.
Air Handler Coil T.C. S.C. KW
MV12B FC/MC36B 1.01 1.02 0.97
MV12B FC/MC42B 1.02 1.03 0.98
MV12B G4FD036H17T2A 1.01 1.02 0.97
MV12B G4FD046H17T2A 1.02 1.03 0.98
MV16C FC/MC36C 1.02 1.03 0.98
MV16C FC/MC42C 1.02 1.03 0.98
MV16C G4FD036H21T2A 1.02 1.03 0.98
MV16C G4FD042H21T2A 1.02 1.03 0.98
AHP36 1.00 1.00 1.00
FC/MC/PC36 1.00 1.00 1.00
FC/MC/PC42 1.00 1.00 1.00
G4FA048S17T2A 1.00 1.00 1.00
G4FD036H17T2A 1.00 1.00 1.00
G4FD036H21T2A 1.00 1.00 1.00
G4FD042H21T2A 1.00 1.00 1.00
G4FD046H17T2A 1.00 1.00 1.00
HC30 1.00 1.00 1.00
UC36 1.00 1.00 1.00
UC42 1.00 1.00 1.00
Variable Speed Furnace Coil T.C. S.C. KW
PV8*A12 FC/MC/PC36A 1.01 1.01 1.01
PV8*B16 FC/MC/PC36B 1.02 1.03 0.98
PV8*C16 FC/MC/PC36C 1.0 1.03 0.98
PV8*C20 FC/MC/PC36C 1.02 1.03 0.94
PV9*A12 FC/MC/PC36A 1.01 1.01 1.01
PV9*B12 FC/MC/PC36B 1.01 1.02 1.01
PV9*C16 FC/MC/PC36C 1.01 1.02 0.97
PV9*C20 FC/MC/PC36C 1.01 1.02 0.97
PV8*B16 FC/MC/PC42B 1.02 1.03 0.98
PV8*C16 FC/MC/PC42C 1.02 1.03 0.94
PV8*C20 FC/MC/PC42C 1.02 1.03 0.94
PV9*B12 FC/MC/PC42B 1.01 1.02 0.97
PV9*C16 FC/MC/PC42C 1.01 1.02 0.97
PV9*C20 FC/MC/PC42C 1.01 1.02 0.97
PV8*B16 G4FA048S17T2A 1.02 1.03 0.98
PV9*B12 G4FA048S17T2A 1.01 1.02 0.97
PV8*B16 G4FD036H17T2A 1.0 1.03 0.98
PV9*B12 G4FD036H17T2A 1.01 1.02 1.01
PV8*C16 G4FD036H21T2A 1.02 1.03 0.98
PV8*C20 G4FD036H21T2A 1.02 1.03 0.94
PV9*C16 G4FD036H21T2A 1.01 1.02 0.97
PV9*C20 G4FD036H21T2A 1.01 1.02 0.97
PV8*C16 G4FD042H21T2A 1.02 1.03 0.94
PV8*C20 G4FD042H21T2A 1.02 1.03 0.94
PV9*C16 G4FD042H21T2A 1.01 1.02 0.97
PV9*C20 G4FD042H21T2A 1.01 1.02 0.97
PV8*B16 G4FD046H17T2A 1.02 1.03 0.98
PV9*B12 G4FD046H17T2A 1.02 1.03 0.98
PV8*A12 HC30 1.01 1.01 1.01
PV9*A12 HC30 1.01 1.01 1.01