York AY012MA321 Air Conditioner User Manual


 
246814-YTG-D-0606
Unitary Products Group 3
Additional R-22 Charge / TXV for Various Matched Systems
Outdoor Unit
AY012MA321 AY018MA321 AY024MA321 AY030MA321 AY036MA321
Required TXV 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1 1TVM2A1
Factory R-22 Charge, lbs-oz 2 - 14 2 - 14 3 - 6 3 - 14 3 - 8
Indoor Coil1 Coil Orifice2 TXV Kit3 - Additional Charge, Oz
FC/MC/PC18A2A 0 0
FC/MC/PC18B2A 0 0
FC/MC/PC24A2A 0
FC/MC/PC24B2A 0
FC/MC/PC30A2A 0
FC/MC/PC30B2A 0
FC/MC/PC36A2A 0 0
FC/MC/PC36B2A 0 0
FC/MC/PC36C2A 0 0
HC24A2A 0 0
HC30A2A 0 0
UC18A2A 0 0
UC18B2A 0 0
UC24A2A 0
UC24B2A 0
UC30A2A 0
UC30B2A 0
UC36A2A 0 0
UC36B2A 0 0
UC36C2A ———0 0—
AHP18B2A 0 0
AHP24B2A 0 0
AHP36C2A 0
FC/MC/PC18A3X 2A + 0 2A + 0
FC/MC/PC18B3X 2A + 0 2A + 0
FC/MC/PC24A3X 2A + 0
FC/MC/PC24B3X 2A + 0
FC/MC/PC30A3X 2A + 0
FC/MC/PC30B3X 2A + 0
FC/MC/PC36A3X 2A + 0 2A + 0
FC/MC/PC36B3X 2A + 0 2A + 0
FC/MC/PC36C3X 2A + 0 2A + 0
FC/MC/PC42B3X 2A + 0 2A + 9
FC/MC/PC42C3X 2A + 0 2A + 9
FC/MC/PC48C3X— ————2A + 9
FC/MC/PC48D3X— ————2A + 9
HC24A3X 2A + 0 2A + 0
HC30A3X 2A + 0 2A + 0
HC48C3X — ————2A + 9
UC18A3X 2A + 0 2A + 0
UC18B3X 2A + 0 2A + 0
UC24A3X 2A + 0
UC24B3X 2A + 0
UC30A3X 2A + 0
UC30B3X 2A + 0
UC36A3X 2A + 0 2A + 0
UC36B3X 2A + 0 2A + 0
UC36C3X 2A + 0 2A + 0
UC42B3X 2A + 0 2A + 9
UC42C3X 2A + 0 2A + 9
UC48C3X — ————2A + 9
UC48D3X — ————2A + 9