WindChaser Products PACR12 Air Conditioner User Manual


 
COOL
DRY
A/C
AUTO
LO
MED
HI
SET
SLEEP
OFF
ON
TIMER
HR
ON/OFF
6. L.C.D. DISPLAY: Indicates the room temperature and
the timer and temperature settings. The unit’s LED displays
the room temperature as soon as the power is turned on
and after the timer or temperature is set.
7. ALARM INDICATOR LIGHT: This light will illuminate
and this unit will shut off when the condensate tank is full
and the unit cannot drain. The light will remain on and the
unit will remain off until the condensation is drained through
Drain (B). Please refer to the TROUBLESHOOTING GUIDE
in this manual for further information.
8. TEMPERATURE REGULATION BUTTONS (UP
AND DOWN): These buttons raise and lower the
thermostat temperature setting by 1º each time they are
pressed, ranging from 61ºF - 90ºF.
9. A/C INDICATOR LIGHT: Illuminates when the
compressor is on and stays solid while the compressor is
running. When the room temperature reaches the set
temperature, the compressor turns off and the light blinks
indicating that the unit has cooled the room to the set
temperature.
10. DEHUMIDIFIER INDICATOR LIGHT: Press the
“FUNCTION” button to select the dehumidification mode.
When the dehumidification mode is on, the temperature
buttons and the fan speed buttons do not function and the
fan will operate on low speed. The dehumidifier indicator
light will illuminate and stay solid while the unit is
dehumidifying. When the humidity in the room is 50% or
lower, the compressor will not run, the unit will not
dehumidify, and the dehumidifier light will blink.
Remember, the exhaust hose does not need to be used in
dehumidifier mode.
NOTE: This unit has a three-minute compressor delay
protection circuit. Thus, the compressor may take up to
three minutes to start from either being switched on or when
changing between the dehumidification and air
conditioning functions.
IF THERE IS A POWER INTERRUPTION WHILE THE
UNIT IS OPERATING, THE UNIT WILL NOT TURN BACK
ON AUTOMATICALLY WHEN THE POWER IS RE-
STORED. THE UNIT MUST BE TURNED BACK ON
MANUALLY. THE UNIT IS DESIGNED WITH THIS
SAFETY FEATURE TO PROTECT THE COMPRESSOR.
(1)
(2)
(3)
(4)
(5)
(6)
CONTROL PANEL FUNCTIONS CONTINUED
REMOTE CONTROL FUNCTIONS
1) Air Conditioning or
Dehumidifier Selector Button
2) A/C Fan Speed Selector Button
3) Thermostat Temperature
Setting UP and DOWN Buttons
4) Sleep Function Button
5) Timer Setting Button
6) Power ON/OFF Button
9