14
Whenever adjusting anticipation, increase
or decrease the displayed number by only
one or two digits, then let the system run for
a while to see if the adjustment is sufficient.
If the heat cycles are too short, press
TIME
FWD
to
increase the cycle time. If the heat cycles
are too long, press
TIME
BACK
to decrease the
cycle time. To set cooling anticipation,
press
SET
CLOCK
and
ADV
DAY
at the same time again.
The display will show COOL 14 (factory
preprogrammed cooling anticipation). Use
the
TIME
FWD
and
TIME
BACK
buttons to adjust anticipa-
tion. Press
RUN
PRGM
to return to your program.
• LOW BATTERY INDICATOR — The three
“AA” alkaline batteries will maintain thermo-
stat programming for approximately one
year if power to the thermostat fails. The
word BATTERY will flash on the display if
the “AA” alkaline batteries are low and should
be replaced. The thermostat will also make
a beeping sound every five minutes when
batteries need replacing. To override the
beeping, press any button on the keypad.
The beeping will stop for 15 hours, then start
again. You may again stop the beeping by
pressing any button on the keypad. After
turning the beep off three times, the thermo-
stat will quit beeping. However, you should
always change the batteries as soon as
possible to ensure that programming will
not be lost in the event of a power outage.
You should also change the batteries at
least once a year.