White Rodgers 1F92W-71 Thermostat User Manual


 
27
Enter Cooling Program
If outside temperature is below 50°F,
we recommend that you remove the
thermostat from the wall before pro-
ceeding with the following steps to pro-
gram cooling temperatures. Personal
injury or property damage may occur
due to air conditioner compressor slug-
ging. A fresh 9 volt Energizer
®
alkaline
battery must be installed to perform
off-wall programming. Programming
away from the wall should prevent ac-
cidental compressor operation. BE
SURE TO PRESS
SYSTEM
HEAT-OFF-COOL-AUTO
TO TURN
THERMOSTAT OFF BEFORE REAT-
TACHING TO THE SUBBASE!
1. Press
SYSTEM
HEAT-OFF-COOL-AUTO
until COOL is displayed.
2. Enter your cooling program by following
the same procedure you followed for en-
tering your heating program.
CHECK YOUR PROGRAMMING
Follow these steps to check your thermostat
programming one final time before beginning
thermostat operation.
1. Press
SYSTEM
HEAT-OFF-COOL-AUTO
until HEAT is displayed.
2. Press and hold
VIEW
PRGM
to view the heating
period times and temperatures in sequence
for weekday, then weekend MOR, DAY,
EVE, and NHT program periods.
3. Press
RUN
PRGM
.
CAUTION
!