Weber FLAME Indoor Fireplace User Manual


 
20
MAINTENANCE
MAIN BURNER FLAME PATTERN
The Weber
®
gas fi replace burner has been factory set for the correct air and
gas mixture. A correct fl ame pattern is:
• A yellow to light-orange fl ame
An incorrect fl ame pattern is:
• A dark orange fl ame
• Smoke-producing fl ame
If the fl ames appear to be darker orange throughout the burner, sooting
occurs, or smoke is produced; follow the burner and spider screen cleaning
procedures.
IGNITION SYSTEM
If the Ignition System fails to ignite the burner, light manually. If Manual igni-
tion is successful, then check the Ignition System.
Check that both the white (2) and black (3) ignition wires are attached
properly.
Check that the igniter button pushes in completely and returns.
Check to see if the igniter is loose in the frame. Tighten if necessary.
If the Ignition System still fails to ignite the burner, see Manual Lighting pro-
cedure and contact your dealer.
(2)
(3)
Printed in U.S.A.