TROUBLESHOOTING
PROBLEM CHECK CURE
Burner burns with a dark orange
ame, in conjunction with heavy soot-
ing.
Inspect Spider / Insect Screen for pos-
sible obstructions. (Blockage of holes.)
Clean Spider / Insect Screen. (See Section
“Annual Maintenance”)
Burner does not light, or fl ame is low
in HIGH position.
Is fuel hose bent or kinked? Straighten fuel hose.
Is igniter functioning properly? Replace igniter (see contact info. below).
Is the igniter box blocked? Remove obstructions from igniter box (see
pg. 10, Step 11 of “Assembly” Section).
Burner fl ame pattern is erratic. Flame
is low when burner is on HIGH. Flames
do not ignite all burner holes.
Are burner holes blocked? Clean burner holes. (See Maintenance Sec-
tion.)
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area