Weber FLAME Indoor Fireplace User Manual


 
19
MAINTENANCE
WEBER
®
SPIDER / INSECT SCREEN
Your Weber
®
gas fi replace, as well as any outdoor gas appliance, is a target
for spiders and other insects. They can nest in the venturi section (1) of the
burner tube. This blocks the normal gas fl ow, and can cause the gas to fl ow
back out of the air shutter. This could result in a fi re, causing serious damage
to your fi replace.
Thus, it is imperative that control compartment, burners and air vents
of the appliance be kept clean.
The burner tube air shutter is fi tted with a stainless steel screen (1) to
prevent spiders and other insects access to the burner tube through the air
shutter openings.
We recommend that you inspect the Spider/Insect screen at least once
a year. (See Section “Annual Maintenance”.) Also inspect and clean
the Spider/Insect screen if any of the following symptoms should ever
occur:
1) The smell of gas in conjunction with the burner fl ame appearing yellow
and lazy.
2) Burner does not ignite.
ƽ DANGER
Failure to correct the above mentioned symptoms may
result in a fi re, which can cause serious bodily injury
or death, and cause damage to property.
(1)
(1)
ANNUAL MAINTENANCE
Inspection and cleaning of the Spider/Insect screen
Brush the spider/insect screen, lightly, with a soft bristle brush (i.e. an old
toothbrush).
ƽ CAUTION: Do not clean the spider/insect screen with
hard or sharp tools. Do not dislodge the spider/insect
screen or enlarge the screen opening.
If the spider/insect screen becomes damaged or cannot be cleaned, call
Weber-Stephen Products Customer Service for replacement parts.
MAIN BURNER CLEANING PROCEDURE
Turn off the gas supply.
1) Remove rain shields.
2) Remove logs and lava rocks.
3) Examine burner holes for blockage.
4) Use a soft bristle brush to remove leaves or other debris.
ƽ CAUTION: Do not enlarge the burner holes when
cleaning.