Weber FLAME Indoor Fireplace User Manual


 
16
OPERATING INSTRUCTIONS
LIGHTING
Summary lighting instructions are on the control panel.
1.
2.
4.
5.
6.
3.
ƽ WARNING: Check hose before each use of fi replace
for nicks, cracking, abrasions or cuts. If the hose
is found to be damaged in any way, do not use the
replace. Replace using only Weber
®
authorized
replacement hose. Contact the Customer Service
Representative in your area using the contact
information on our web site. Log onto www.weber.
com
®
.
1) Remove rain shields.
ƽ DANGER
Failure to remove rain shields while igniting the
replace’s burners, or not waiting 5 minutes to allow
the gas to clear if the fi replace does not light, may
result in an explosive fl ame-up which can cause
serious bodily injury or death and damage to property.
2) Make sure the burner control knob is turned OFF. (Push control knob
down and turn clockwise to ensure that it is in the OFF position.)
3) Turn the gas supply valve on.
ƽ WARNING: Do not lean over the open fi replace. Keep
your face and body at least one foot away from the
logs when lighting the fi replace. Leaning over a lit
replace could cause damage to body and personal
property.
4) Push burner control knob in and turn counter-clockwise to START/HI.
5) Push in igniter several times, until burner is lit.
6) Check that the burner is lit.
ƽ WARNING:
If the burner does not light, turn the burner control
knob to OFF and wait 5 minutes to let the gas clear
before you try again or try to light with a match. Failure
to comply with these measures could result in an
explosive fl ame-up which can cause serious bodily
injury or death and damage to property.
Note: Normal burning pattern will develop light soot on log set. If heavy
sooting occurs, refer to troubleshooting.
TO EXTINGUISH
Push in the burner control knob and turn clockwise to the OFF posi-
tion. Turn gas supply OFF at the source. When unit has cooled, replace
rain shields.
ƽ WARNING
Inspect the burner before each use of the fi replace. If
it is evident that the burner is damaged in any way, it
must be replaced with a burner specifi ed by the manu-
facturer prior to the fi replace being turned on. Failure
to comply with these measures could result in an ex-
plosive fl ame-up which can cause serious bodily injury
or death and damage to property.