Note:
If the calculation for the system capacity
exceeds 9999 gallons (99.99 cubic meters) (P5,
Capacity, divided by P3, Hardness,) the control will
display 9999 (99.99) for capacity until the water usage
has dropped the remaining capacity below that
number. When water is flowing through the system, the
colon in the Time of Day display will blink.
At this time, all of the mandatory parameters are filled
and the control is ready for operation. The display will
alternate between the Time of Day and Capacity if no
keys are pressed for 30 seconds. The Capacity value is
the volume remaining in gallons (cubic meters for
metric) before a regeneration is needed.
Verify proper power outage operation by briefly
removing power to the control. The unit will beep and
show the time of day when power is turned on.
If you wish to fine-tune the operation of this control,
refer to Table 3 for details concerning allowable values,
defaults, and parameter descriptions. The
programming procedure is the same for all of these
parameters.
Table 1 - Programming Parameters
Parameter
Range of
Values
Minimum
Increments
Default
Units of
Measure
Notes
Name Description
P1
Time of day
AM or PM
1:00 to 12:59
00:00 to 23:59
1 None Hour:minute
Range depends on value
selected for P13. Enter the
current time.
P2
Time of day
of
regeneration
1:00 to 12:59
AM or PM
00:00 to 23:59
1 2:00 AM Hour:minute
Range depends on value
selected for P13. Skip this
parameter to accept the
default or enter a new time.
P3
Hardness of
water
3 to 250
30 to 2500
1
10
10
100
Grains/gallon
mg/L
Unit of measure depends on
value selected for P12. Test
water hardness and enter
that value.
P4 Salt amount
0.5 to 99.5
0.1 to 25.5
0.5
0.1
6
2.5
Pounds
Kilograms
Unit of measure and default
depends on value selected
for P12. Refer to Table 2.
P5
Capacity of
unit
0.1 to 140.0
0.01 to 14.00
0.1
0.01
1.0
0.1
Kilograins
Kilograms
Unit of measure depends on
value selected for P12. Enter
the unit capacity.
Table 2 - Suggested Salt Settings
(
Pounds of Salt for Various Size Conditioners)
Resin Bed Volume
Kilograins of
Hardness
Capacity
Setting
0.5 ft
3
0.75 ft
3
1.0 ft
3
1.25 ft
3
1.5 ft
3
1.75 ft
3
2.0 ft
3
124.5- - ----
169.05.0- ----
20-8.56.0----
24 - 14.0 8.5 7.0 - - -
30 - - 15.0 11.0 9.0 - -
32 - - 18.5 12.5 10.0 9.0 -
35 - - - 16.0 12.0 10.0 9.0
40 - - - 23.0 17.0 14.0 12.0
48 - - - - 28.0 21.0 17.0