Vulcan-Hart ML-52201 Boiler User Manual


 
– 7 –
Manifold Cover Assembly
(GHCB40 & GHIR44)
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
1. Remove the grease tray from the broiler
(GHCB40 only).
NOTE: The GHIR44 manifold cover assembly has
a chain to protect switch wiring.
2. Loosen the mounting screw in each burner
knob.
3. Remove the two burner knobs from the broiler.
4. Remove the two screws from the manifold
cover assembly.
5. Remove the manifold cover assembly from
the broiler.
6. Reverse the procedure to install.
Burner Knob Cover Plate [
HCB2(B), IR1 and IR2(B)]
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
1. Loosen the mounting screw in each burner
knob.
2. Remove the burner knob.
3. Remove two screws from the burner knob
cover plate and the broiler.
4. Slide the burner knob cover plate out and
remove it from the broiler.
5. Reverse the procedure to install.