Vulcan-Hart ML-52201 Boiler User Manual


 
– 26 –
3. Remove the two cotter pins and washers from
the lower lever arm assembly.
4. Remove the lower lever arm assembly from
the two brackets.
5. Reverse the procedure to install.
BLOWER AND MOTOR
GHIR44
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
1. Open the lower doors to get access to the
blower and motor.
2. Remove the four screws from the bracket and
blower and motor.
3. Move the bracket away from the blower and
motor.
4. Remove the four screws and nuts from the air
duct and the blower and motor.
5. Carefully remove the six screws from the
blower and motor and the brackets.
6. Remove the air duct from the broiler.
7. Note the location and connection of the
electrical wires.