Vulcan-Hart ML-52201 Boiler User Manual


 
– 25 –
LEVER ARM ASSEMBLY
(ALL MODELS)
Upper
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN OPEN
FLAME.
1. Remove the grid carriage assembly as
outlined in Grid Carriage Assembly.
2. Remove the two cotter pins and washers from
the upper lever arm assembly.
3. Remove the upper lever arm assembly from
the two brackets.
4. Reverse the procedure to install.
Lower
WARNING: SHUT OFF THE GAS BEFORE
SERVICING.
WARNING: ALL GAS JOINTS DISTURBED
DURING SERVICING MUST BE CHECKED FOR
LEAKS. CHECK WITH SOAP AND WATER
SOLUTION (BUBBLES). DO NOT USE AN OPEN
FLAME.
1. Remove the grid carriage assembly as
outlined in Grid Carriage Assembly.
2. Remove two screws and the lower lever cover
from the broiler.