BYPASSING PROTECTION ZONES
Using the 6
BYPASS Key
This key is used when you want to arm your system with one or more zones
intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm
when violated while your system is armed. All bypasses are removed when an OFF
sequence (security code plus OFF) is performed. Bypasses are also removed if the
arming procedure that follows the bypass command is not successful.
The system will not allow fire zones to be bypassed.
To bypass zones, the system must be disarmed first.
BYPASS
1. + 6 ENTER SECURITY CODE THEN PRESS BYPASS
(Security Code)
Example: 7 2 9 6 then press the BYPASS key.
2.
ENTER ZONE NUMBERS
(Zone Numbers) Enter the zone number(s) for the zones to be bypassed
(e.g., 01, 02, 03, etc.).
Important! All single-digit numbers must be preceded
by a zero (for example, enter 01 for zone 1).
3.
BYPASS 07 FRONT
UPSTAIRS BEDROOM
Typical bypass message
WAIT
The keypad will display the word BYPASS along with
each bypassed zone number. Wait for these zones to
be displayed, to be sure that intended zones are
bypassed.
4.
DISARMED BYPASS
READY TO ARM
ARM AS USUAL
Arm the system as usual when the keypad displays the
"Ready ” message.