Viking Access Systems UL 991 Garage Door Opener User Manual


 
TECHNICAL SUPPORT 1 800 908 0884
29
SOLAR PANEL INSTALLATIONSOLAR PANEL INSTALLATION
For Viking Vehicular Gate Operators
STEP 1
Use a 24V solar panel or two solar panels of 12V
in series with a total capacity of 40 Watts..
STEP 3
Replace the existing batteries with a battery pack
of 33AHr or greater.
STEP 2
Connect the solar panel cables to the power
harness as shown. Make sure you cut the wires
coming from the toroidal transformer.
STEP 4
Refer to the maps provided to get an idea about the
number of cycles the gate will be operated per day.
This figure is for a single gate operator with just:
a) One Radio reiver,
b) One low voltage low current loop detector and
c) One low voltage, low current photo cell
Radio Station
Mag.
Lock
Mag. Lock
Safety ConnectorOpen CommandsGuard StationMaster/Slave
Brake
UL
Siren
Radio
Rec.
UL
Sensor
OPEN RIGHT
24V BAT 24VAC
OPEN LEFT
Safety
Loop
Center
Loop
Obstruction
Sensor
Charger
Power
Low Battery
Motor Sensor
Hold Open
Timer
Stop
Overlap Delay
Close Open
Obstruction
Sensor
min. MAX
Overlap
Delay
1.5
0
3
Radio StationLoop ConnectorOpen CommandsGuard StationMaster/Slave
GND
Close
Stop
Open
GND
Close
Stop
Open
Gnd
Fire
Gnd
Strike
Gnd
Exit
Gnd
Center
Gnd
Reopen
Gnd
UL
Gnd
+28v
Gnd
Radio
Gnd
+28v
+28v
Mag.
Lock
Fail
S
afe/Secure
MAG. LOCK
N.C.
COM
N.O.
Charger
Power
Low Battery
Motor Sensor
Hold Open
Timer
Stop
Close
Open
30
60
Off
1
Radio
Rec.
UL
Sens
Safety
Loop
Center
Loop
Brake
Siren
Connect Leads from
Solar Panel(s), Polarity 
is not important
Cut the Leads
to the Toroidal
Transformer
+
+
+
Reuse Existing
Battery Fuse Holder
Connect New
Batteries to
Existing Leads
Observing Polarity
Red Wire
Black Wire
+
+
Connect To Gate
Operator Input Block
24 VDC
Panel
12 VDC
Panels
2
*With a 40 Watt (24VDC) Panel System.
5
8
10
12
14
Number of
Cycles per Day*
January July
NOTE –
1. Remember that the sun is your only source of energy.
2. The greater capacity of the batteries, the longer the system will operate on
cloudy days.
3. If more spcific information is needed, please consult with Viking Access Systems.
For more information regarding solar energy refer to http:/www.nrel.gov.