9. Venting Cont.
9.3 Choice of flue:
The following flue kits are available for connecting to the boiler:
A
Standard coaxial horizontal flue kit (Exhaust & intake outside)
Figure 9.3 (Coaxial 2.4/4.0 inches – nominal lenght 3.3 ft)
It can be fitted to allow discharge to the rear or either side of the boiler via the
flanged boiler adapter elbow. Minimum lenght required is 1 ft. Maximum equivalent
lenght of 32.8 ft can be achieved utilising extensions. This flue system can only be
used to discharge horizontally, it is not designed to enable termination in the
vertical plane.
Installation:
• Drill hole A (on the wall template) through the outside wall.
• Cut the pipe as necessary so that a no more than 6” protrudes from the house.
• Slide the intake and exhaust pipes through the hole.
• Slide one rubber wall trim piece on the pipe from inside and one from outside.
• Connect exhaust (inner) pipe to concentric elbow.
• Connect intake (outer) pipe to concentric elbow.
• Secure elbow to boiler using gasket and four screws provided.
• Secure end cap on the intake pipe outside the house.
RIVA HEAT ONLY MANUAL - REV A
18